Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30850233 <br />TTH27-33 <br />C 1 A <br />Jack -Open <br />4 <br />1 <br />Job Reference (optional) <br />builders Flrstbource (1 amps, FL), I amps, FL - 33b64, <br />2x4 = <br />5.630 S Nov 19 2022 MITek Industries, Inc. Mon Jun 19 12:29:23 2023 Page 1 <br />I D: tP uYCeVfQTfYt30 C?ZvfnpzlGU H-RfC?PsB7OH q3N Sg PgnL8w3u ITXbG K WrC Doi7J4zJC?f <br />1-7-10 <br />1-7-10 <br />Scale = 1:9.0 <br />1-7-10 <br />1-7-10 <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. in (loc) I/deft Ud <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.12 <br />Vert(LL) -0.00 2 >999 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.03 <br />Vert(CT) -0.00 2 >999 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.00 <br />Horz(CT) -0.00 3 n/a n/a <br />BCDL 10.0 <br />Code FBC2020/TP12014 <br />Matrix-P <br />Weight: 7 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-7-10 oc purlins. <br />BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical <br />Max Horz 2=82(LC 12) <br />Max Uplift 3=-26(LC 9), 2=-122(LC 12) <br />Max Gray 3=31(LC 17), 2=132(LC 1), 4=32(LC 3) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />NOTES- (7) <br />1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30R; eave=oft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />5) Refer to girder(s) for truss to truss connections. <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) <br />2=122. <br />7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Joagmlm Velez PE N..68182 <br />NB7ek1ma. DBA VBTek ISA FL Ceri 6634 <br />16023 SwWgley R1dge Rd. <br />Chesterfield, N10 63017 <br />Date: <br />June 20,2023 <br />A WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MTk® econnectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117Pl1 quality Criteria, D88-89 and BCS/ Building Component 16023 Swingley Ridge Rd <br />Safely Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />