My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Elby Ln (2)
Zephyrhills
>
Building Department
>
Building Plans
>
Elby Ln (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 4:37:16 PM
Creation date
2/18/2025 4:52:41 PM
Metadata
Fields
Template:
Building Plans
Location
Elby Ln
Contractor
Starlight Homes
Description
Tyson 7 Plex
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30850235 <br />TTH27-33 <br />CA <br />Jack -Open <br />4 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Mon Jun 19 12:29:24 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />-1-0-0 1-4-14 <br />6 <br />m <br />0 <br />2x4 = <br />Scale = 1:7.4 <br />LOADING (pso <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2020/TPI2014 <br />CSI. <br />TC 0.12 <br />BC 0.02 <br />WB 0.00 <br />Matrix-P <br />DEFL. in floc) Vdefl Ud <br />Vert(LL) -0.00 2 >999 240 <br />Vert(CT) -0.00 2 >999 180 <br />Horz(CT) 0.00 3 file n/a <br />PLATES GRIP <br />MT20 2441190 <br />Weight: 6 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-4-14 oc purlins. <br />BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical <br />Max Horz 2=65(LC 12) <br />Max Uplift 3=-17(LC 9), 2=-129(LC 12) <br />Max Grav 3=19(LC 17), 2=127(LC 1), 4=27(LC 3) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />NOTES- (7) <br />1) Wind: ASCE 7-16; Vuk=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. <br />4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />5) Refer to girder(s) for truss to truss connections. <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) <br />2=129. <br />7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Jr agolo Velez PE N..68182 <br />NEIek Luc. DBA.Mck USA FLCcrt6634 <br />16023 Swinitky Ridge Rd. <br />Chesterfield, 310 63017 <br />Date: <br />June 20,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTekP <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYrPN Duality Criteria, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.