Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30850237 <br />TTH27-33 <br />E.15 <br />Jack -Open <br />34 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Mon Jun 1912:29:25 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />-1-0-0 5-M <br />1-0-0 5-0-0 <br />3x4 = <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />YES <br />BCDL <br />10.0 <br />Code FBC2020/TPI2014 <br />LUMBER - <br />TOP CHORD 2x4 SP No.2 <br />BOT CHORD 2x4 SP No.2 <br />REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical <br />Max Horz 2=173(LC 12) <br />Max Uplift 3=-137(LC 12), 2=155(LC 12) <br />Max Grav 3=134(LC 17), 2=247(LC 1), 4=96(LC 3) <br />5-0-0 <br />CSI. <br />DEFL. <br />in <br />(loc) <br />I/deft <br />L/d <br />TC 0.76 <br />Vert(LL) <br />-0.03 <br />2-4 <br />>999 <br />240 <br />BC 0.28 <br />Vert(CT) <br />-0.06 <br />2-4 <br />>909 <br />180 <br />WB 0.00 <br />Horz(CT) <br />-0.00 <br />3 <br />n/a <br />n/a <br />Matrix-P <br />FORCES. (lb) - Max. Camp./Max. Ten. - All forces 250 (lb) or less except when shown <br />Scale = 1:17.4 <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 18 Ib FT = 20% <br />BRACING - <br />TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. <br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />NOTES- (7) <br />1) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 4-114 zone; cantilever left <br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />5) Refer to girder(s) for truss to truss connections. <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) <br />3=137, 2=155. <br />7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />This item has been <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Joagnln Velez PE No.69192 <br />D'BTek Inc. DBA MiTek USA M Cert6634 <br />16023 Swingley Ridge Rd. <br />Ckesrerneld, MO 63017 <br />Dare: <br />June 20,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYMI Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />