Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641486 <br />TTH119-125 <br />T07A <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSoume (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:22:17 2023 Page 1 <br />I D:IPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?P s B7OH q3N SgPgnL8w3u ITXbGK WrC Doi7J 4zJC?f <br />13-0-0 19-1-8 2110-8 30-0-0 35-11-15 43-0-0 <br />-0- 7-0-1 5-11-15 6-1-8 4-9-0 6-1-8 5-11-15 7-0-1 <br />5x6 = <br />5.00 12 <br />5x8 = <br />Scale = 1,75.1 <br />3x8 = I to n 10 15 tit 14 a es Z4 14 3x8 = <br />3x4 = <br />5x6 WI3 = 3x8 = 3x4 = 5x6 WB = <br />3x4 = <br />LOADING (pso <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2020ITP12014 <br />CSI. <br />TC 0.75 <br />BC 0.96 <br />WB 0.41 <br />Matrix-SH <br />DEFL. in floc) I/deft L/d <br />Vert(LL) -0.40 12-14 >999 240 <br />Vert(CT) -0.70 12-14 >729 180 <br />Horz(CT) 0.17 11 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 227 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. <br />1-4,9-11: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. <br />BOT CHORD 2x4 SP 285OF 2.0E or 2x4 SP M 31 *Except* WEBS 1 Row at midpt 5-15, <br />7-15, 8-14 <br />13-16: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />OTHERS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 11=0-3-8 <br />Max Horz 2=265(LC 11) <br />Max Uplift 2=-944(LC 12), 11=857(LC 12) <br />Max Grav 2=1871(LC 17), 11=1819(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3900/2055, 3-5=-3656/1944, 5-6=-2629/1554, 6-7=-2389/1507, 7-8=-2633/1549, <br />8-10=-3669/1950,10-11=-3914/2074 <br />BOT CHORD 2-17=-1808/3727, 15-17=-1466/3104, 14-15=-1038/2387, 12-14=145512952, <br />11-12=-1805/3550 <br />WEBS 3-17=-351/346, 5-17=-214/750, 5-15=877/557, 6-15=-331/763, 7-14=-327/837, <br />8-14=-881/560, 8-12=-238/757, 10-12=354/365 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Exterior(2E) <br />This item has been <br />19-1-8 to 23.10-8, Exterior(2R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 42-10-4 zone; cantilever left and right exposed ; end vertical <br />electronically signed and <br />left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />sealed by Velez, Joaquin, PE <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />using a Digital Signature. <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />Printed Copies Of this <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />document are not considered <br />6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />signed and sealed and the <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />signature <br />nature must be verified <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at <br />joint 11. <br />on any electronic Copies. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />.r-qui. Velez PE ce.68182 <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />wT#k1— DBA31fTekUSA FL Cen 6634 <br />16023 Svsingiey Ridge Rd. <br />Chesterfield, MO 63017 <br />Dare: <br />May 25,2023 <br />WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ' <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/nolf Quality Criteria, DSB-89 and BCS/ Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />