My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38054-38082 Elby Ln (2)
Zephyrhills
>
Building Department
>
Building Plans
>
38054-38082 Elby Ln (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:05:54 AM
Creation date
2/19/2025 7:57:47 AM
Metadata
Fields
Template:
Building Plans
Street #
38054-38082
Location
Elby Ln
Contractor
Starlight Homes
Building Plans - Permit #
6565-6570
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641491 <br />TTH119-125 <br />Vol <br />GABLE <br />1 <br />1 <br />Job Reference (optional) <br />Builders FIrStSource (Tampa, FL), Tampa, FL - 33554, <br />2x4 <br />8.630 s Nov 19 2022 MITek Industries, Inc. Wed May 24 11:22:24 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />TRUSS DESIGNED FOR WIND LOADS IN THE PLANE Scale = 1:17.8 <br />4x4 —_ OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND <br />(NORMAL TO THE FACE), SEE STANDARD INDUSTRY <br />GABLE END DETAILS AS APPLICABLE, OR CONSULT <br />QUALIFIED BUILDING DESIGNER AS PER ANSI/rPl 1. <br />2x4 11 2x4 11 2x4 11 <br />2x4 <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2020/TP12014 <br />CSI. <br />TC 0.17 <br />BC 0.13 <br />WB 0.11 <br />Matrix-SH <br />DEFL. in floc) Well Ud <br />Vert(LL) n/a n/a 999 <br />Vert(CT) n/a n/a 999 <br />Horz(CT) 0.00 5 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 38 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. <br />BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. <br />OTHERS 2x4 SP No.3 <br />REACTIONS. All bearings 11-1-0. <br />(lb) - Max Horz 1=55(LC 11) <br />Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 8=-184(LC 12), 6=184(LC 12) <br />Max Grav All reactions 250 lb or less atjoint(s) 1, 5, 7 except 8=279(LC 1), 6=279(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />WEBS 2-8=-187/368, 4-6=187/368 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 5-6-8, Exterior(2R) 5-6-8 to <br />8-6-8, Interior(1) 8-6-8 to 103-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and <br />forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Gable requires continuous bottom chord bearing. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except <br />This item has been <br />(jt=lb) 8=184, 6=184. <br />electronically signed and <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />sealed by Velez, Joaquin, PE <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Joagal. Velez PE'-68182 <br />NbTek lue. DBA 31fTek USA FL Cerf 6694 <br />16023 Swingley Ridge Rd. <br />Cbeslerfldd. MO 63017 <br />Date: <br />May 25,2023 <br />-- <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only wdh MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.