Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641902 <br />TTH115-118 <br />T05 <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 Is Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:27:55 2023 Page 1 <br />I D: tP uYC eVfQTfYt3OC?ZvfnpzlG U H-RfC?P sB7OHg3N Sg Pqn L8w3u ITXbG KWrC Doi7 J4zJC?f <br />1-0 Q 8 4 4 15-9-10 21 6-0 27-2-6 34-7-12 43-0-0 44-0-p <br />8-4-4 7-5-5 5S6 5-8-6 7-5-5 844 <br />5.00 12 <br />5x8 = 2x4 II 5x8 = <br />5 18 6 1920 21 7 <br />Scale = 1:75.2 <br />3x8 = 16 15 " 14 `v 13 12 3x8 = <br />2x4 II <br />5x6 = <br />3x8 = <br />5x6 = <br />2x4 11 <br />8-4-4 15-9-10 21-6-0 27-21 34-7-12 43-0-0 <br />8-4-4 7-5-5 51. 5-8� 7-5-5 8-4-4 <br />Plate Offsets (X,Y)— [2:0-4-2,0-1-81, [5:0-5-12,0-2-81, [7:0-5-12,0-2-81, [10:0-4-2,0-1-81, 113:0-3-0,0-3-01, [15:0-3-0,0-3-01 <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />CSI. <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TC 0.97 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BC 0.88 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />YES <br />WB 0.36 <br />BCDL <br />10.0 <br />Code FBC2020/TPI2014 <br />Matrix-SH <br />LUMBER - <br />TOP CHORD <br />2x4 SP No.2 `Except" <br />1-4,8-11: 2x4 SP No.1 <br />BOT CHORD <br />2x4 SP No.1 'Except' <br />13-15: 2x4 SP No.2 <br />WEBS <br />2x4 SP No.3 <br />DEFL. in (loc) I/defl Ud <br />Vert(LL) 0.36 14 >999 240 <br />Vert(CT) -0.56 14-15 >920 180 <br />Horz(CT) 0.20 10 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 222 lb FT = 20 <br />BRACING - <br />TOP CHORD Structural wood sheathing directly applied. <br />BOT CHORD Rigid ceiling directly applied or 4-6-5 oc bracing. <br />WEBS 1 Row at midpt 3-15, 9-13 <br />Ie <br />0 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=-223(LC 10) <br />Max Uplift 2=-943(LC 12), 10=943(LC 12) <br />Max Grav 2=1861(LC 17), 10=1861(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3888/2047, 3-5=-2973/1686, 5-6=2882/1743, 6-7=2882/1743, 7-9=2973/1686, <br />9-10=-3889/2047 <br />BOT CHORD 2-16=-1752/3670, 15-16=-1752/3670, 14-15=-1217/2786, 13-14=1230/2675, <br />12-13=-1766/3503, 10-112=1766/3503 <br />WEBS 3-16=0/345, 3-15=980/593, 5-15=210/669, 5-14=-198/447, 6-14=-337/305, <br />7-14=-198/447, 7-13=-210/670, 9-13=-981/593, 9-12=0/345 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) <br />15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 44-0-0 zone; cantilever left and <br />This item has been <br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 <br />electronically signed and <br />plate grip DOL=1.60 <br />sealed by Velez, Joaquin, PE <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />using a Digital Signature. <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />Printed Copies Of this <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />document are not Considered <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />signed and sealed and the <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />signature must be verified <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) <br />2=943, 10=943. <br />On any electronic Copies. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />Jragnla Velez PE N0.68182 <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />aniek I— DBA nvTek USA FL C,n 6614 <br />16023 Sniag.y Ridge Rd. <br />Chesterfield. 3IO 63017 <br />Date: <br />May 25,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />