Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />City <br />Ply <br />T30641909 <br />TTH115-118 <br />T10 <br />Common <br />16 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:28:09 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3uITXbGKWrCDoi7J4zJC?f <br />-1-0-Q 7-7-3 14-6-10 21-6-0 28-5-6 35-4-13 43-0-0 V-0-Q <br />I—O-� 7-7-3 6-11-6 6-11� 6-11-6 6-11-6 7-7-3 .0- <br />d <br />5x6 = <br />5.00 12 <br />Scale = 1:72.2 <br />3x8 = I r cc ro —ram cv — w 1 � co u - 3x8 = <br />3x4 = 4x6 = <br />3x4 = <br />3x4 = <br />4x6 = <br />33-11-10 <br />3x4 = <br />43-0-0 <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 * <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2020ITP12014 <br />CSI. <br />TC 0.91 <br />BC 0.92 <br />WB 0.99 <br />Matrix-SH <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />in (loc) I/deft L/d <br />-0.40 14-15 >999 240 <br />-0.68 14-15 >751 180 <br />0.18 10 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 218 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 *Except* <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />1-4,8-11: 2x4 SP ND.1 <br />BOT CHORD <br />Rigid ceiling directly applied or 2-2-0 oc bracing. <br />BOT CHORD 2x4 SP No.1 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=-298(LC 10) <br />Max Uplift 2=-943(LC 12), 10=943(1-C 12) <br />Max Grav 2=1885(LC 17), 10=1885(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3931/2002, 3-5=-3802/2010, 5-6=2890/1661, 6-7=2890/1661, 7-9=3802/2010, <br />9-10=-3932/2002 <br />BOT CHORD 2-17=-170813783, 15-17=-1306/3020, 14-15=-850/2218, 12-14=-1307/2872, <br />10-12=-1708/3560 <br />WEBS 6-14=-520/1153, 7-14=-763/574, 7-12=392/909, 9-12=362/365, 6-15=-520/1153, <br />5-15=-763/574, 5-17=-392/908, 3-17=362/365 <br />NOTES- (7) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) <br />21-6-0 to 25-9-10, Interior(1) 25-9-10 to 44-0-0 zone; Cantilever left and right exposed ; end vertical left and right exposed;C-C for <br />members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />This item has been <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />electronically signed and <br />to the use of this truss component. <br />sealed by Velez, Joaquin, PE <br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />* <br />using a Digital Signature. <br />5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL =1 O.Opsf. <br />Printed copies of this <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) <br />document are not considered <br />2=943,10=943. <br />signed and sealed and the <br />7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />signature must be verified <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />on any electronic copies. <br />Jongaia Velez PE N.,68182 <br />iBTek Iuc. DBA \BTek USA FL Cer(6634 <br />16023 Shingle) Ridge Rd. <br />Chesterfield, MO 63017 <br />D. te: <br />May 25,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/192020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSbTPIi Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />