Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T30641896 <br />TTH115-118 <br />HJ5 <br />Diagonal Hip Girder <br />4 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Wed May 24 11:27:38 2023 Page 1 <br />ID:tPuYCeVfQTfYt30C?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3uITXbGKWrCDoi7J4zJC?f <br />-1-6-12 7-8-13 <br />1&12 7-8-13 <br />3x4 = <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />CSI. <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TC 0.91 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BC 0.76 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />NO <br />WB 0.00 <br />BCDL <br />10.0 <br />Code FBC2020/TP12014 <br />Matrix-SH <br />LUMBER - <br />TOP CHORD <br />2x4 SP No.2 <br />BOT CHORD <br />2x4 SP No.2 <br />REACTIONS. <br />(size) 3=Mechanical, 2=0-4-9, 4=Mechanical <br />Max Horz 2=172(LC 8) <br />Max Uplift 3=-180(LC 8), 2=283(LC 8) <br />Max Gram 3=183(LC 1), 2=388(LC 1), 4=148(LC 3) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />Scale = 1:17.2 <br />7-8-13 <br />7-8-6 <br />DEFL. in (loc) I/defl Ud PLATES GRIP <br />Vert(LL) 0.15 2-4 >603 240 MT20 244/190 <br />Vert(CT) -0.33 2-4 >276 180 <br />Horz(CT) -0.00 3 n/a n/a <br />Weight: 26 lb FT = 20% <br />BRACING - <br />TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. <br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />NOTES- (9) <br />1) Wind: ASCE 7-16; VuH=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=oft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />5) Refer to girder(s) for truss to truss connections. <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) <br />3=180, 2=283. <br />7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 104 lb down and 23 lb up at <br />1-6-10, 85 lb down and 34 lb up at 2-6-11, and 47 lb down and 106 Ib up at 4-8-1, and 108 lb down and 95 lb up at 5-1-14 on top <br />chord, and 5 lb down at 1-6-10, 8 lb down at 2-6-11, and 27 lb down at 4-8-1, and 23 lb down at 5-1-14 on bottom chord. The <br />design/selection of such connection device(s) is the responsibility of others. <br />8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). <br />9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />LOAD CASE(S) Standard <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 <br />Uniform Loads (plf) <br />Vert: 1-3=-54, 2-4=20 <br />Concentrated Loads (lb) <br />Vert: 7=-3(F) 8=-2(B) 11=-5(F) 12=-5(B) <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Jaagatn Velez PE N..69192 <br />JBTek Iuc. DBA \BTek USA FL Cert6634 <br />16023 Swiaglec Ridge Rd. <br />Chesterfield. 310 63017 <br />Date: <br />May 25,2023 <br />O WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUrpl1 Qua14 Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd <br />Safety Irdormatlon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />