Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31961933 <br />TTH56-63 <br />V07 <br />GABLE <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSouroe (Tampa, FL), Tampa, FL - 33564, <br />8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 2617:06:49 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />04 = <br />Scale = 1:24.4 <br />1 <br />6 <br />6 <br />3x4 <br />16 <br />15 <br />14 <br />13 <br />12 <br />11 <br />10 <br />3x4 <br />14-7-8 <br />14-7-8 <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />CSI. <br />DEFL. <br />in (loc) <br />I/deft <br />L/d <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL <br />1.25 <br />TC <br />0.09 <br />Vert(ILL) <br />n/a <br />n/a <br />999 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL <br />1.25 <br />BC <br />0.08 <br />Vert(CT) <br />n/a <br />n/a <br />999 <br />BCLL 0.0 <br />Rep Stress Incr <br />YES <br />WB <br />0.07 <br />Horz(CT) <br />0.00 9 <br />n/a <br />n/a <br />BCDL 10.0 <br />Code FBC2020/TP12014 <br />Matrix-SH <br />Weight: 64 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. <br />BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />OTHERS 2x4 SP No.3 <br />REACTIONS. All bearings 14-7-8. <br />(lb)- Max Horz 1=112(LC11) <br />Max Uplift All uplift 100 lb or less at joint(s) 1, 9, 14, 15, 12, 11 except 16=146(LC 12), 10=146(LC 12) <br />Max Grav All reactions 250 lb or less at joint(s) 1, 9, 13, 14, 15, 16, 12, 11, 10 <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />NOTES- (9) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-9 to 3-7-9, Interior(1) 3-7-9 to 7-3-12, Exterior(2R) 7-3-12 <br />to 10-3-12, Interior(1) 10-3-12 to 13-11-15 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for <br />members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) All plates are 2x4 MT20 unless otherwise indicated. <br />5) Gable requires continuous bottom chord bearing. <br />6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 9, 14, 15, 12, <br />This item has been <br />11 except (jt=lb) 16=1 46, 1 0=1 46. <br />electronically signed and <br />9) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />sealed by Velez, Joaquin, PE <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />3--hilt Velez PE "..68182 <br />lhiek for, DBA DTek USA FL Celt 4634 <br />16023 Saingley Ridge Rd. <br />Chesterfield. M0 63017 <br />Date: <br />October 27.2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek* <br />a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damagge. For general gguidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSM11 Quakty Criteria and OSB-22 available from Truss Plate Institute (www.tpinsLorg) Chesterfield, MO 63017 <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314,434.1200 / MTek-US.com <br />