Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />]Job <br />T31961937 <br />TTH56-63 <br />V11 <br />Valley <br />1 <br />1 <br />Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, <br />8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:53 2023 Page 1 <br />I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3NSgPgn L8w3u ITXbGKWrC Doi7J 4zJC?f <br />7-8-0 <br />Scale = 1:14.2 <br />4x4 = <br />3x4 � 2x4 II 3x4 <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. <br />in (loc) I/deft Ud <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.18 <br />Vert(LL) <br />n/a n/a 999 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.15 <br />Vert(CT) <br />n/a n/a 999 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.09 <br />Horz(CT) <br />0.00 3 n/a n/a <br />BCDL 10.0 <br />Code FBC2020/TP12014 <br />Matrix-SH <br />Weight: 23 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD <br />Structural wood sheathing directly applied or 6-0-0 oc purlins. <br />BOT CHORD 2x4 SP No.2 <br />BOT CHORD <br />Rigid ceiling directly applied or 10-0-0 oc bracing. <br />OTHERS 2x4 SP No.3 <br />REACTIONS. (size) 1=7-8-0, 3=7-8-0, 4=7-8-0 <br />Max Horz 1=-35(LC 10) <br />Max Uplift 1=-60(LC 12), 3=60(LC 12), 4=-127(LC 12) <br />Max Grav 1=102(LC 21), 3=102(LC 22), 4=258(LC 1) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />WEBS 2-4=-159/296 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Gable requires continuous bottom chord bearing. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift atjoint(s) 1, 3 except Qt=lb) <br />4=127. <br />This item has been <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />electronically signed and <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />1—I.in Velez PE No.68182 <br />Alfektut. DBA lffek USA F7.Cer16634 <br />16023 Swngley Ridge Rd. <br />Ciexierfieid, Mo 63017 <br />Date: <br />October 27.2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. ■ <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and BCSI Building Component Safety Information available from the Stmetural Building Component Association (www.sbcsmmponents.com) 314.434.1200 / MTek-US.com <br />