Job
<br />Truss
<br />Truss Type
<br />Qty
<br />Ply
<br />T31961912
<br />TTH56 63
<br />Tot
<br />Hip Girder
<br />2
<br />Job Reference (optional)
<br />t1Ulldefs rlrstsource ( I ampa, t-L), I ampa, h L - 335154, 6.b3U s Aug sU 2U23 MI I eK industries, Inc. I nu UCt Z6 1 t:Ub:Z1 ZUZ3 vage 1
<br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3u ITXbGKWrCDoi7J4zJC?f
<br />-�1-0-Q 6-2-0 11-4-12 16-5-6 21-0-0 26-6-10 31-7-4 36-9-10 43-0-0 Q4-0-p
<br />i-0 d 6-2 6 5-2 6 5 0 10 5-0.10 5-0-10 5-0-10 5-2-6 1 6-2-6 -0-
<br />5.00 12 7x8 =
<br />3
<br />2x4 11 48 = 7x8 = 48 = 2x4 11 7x8 —
<br />21 22 4 23 24 5 2526 27 6 28 2930 7 31 32 8 33 34 9
<br />Scale = 1:73.6
<br />5x8 = 20 35 36 19 37 38 1817 39 40 16 41 42 1514 43 44 13 45 46 12 5x8 =
<br />2x4 11 5x8 = 7x8 WB = 4x8 = 2x4 11 5x8 = 2x4 11
<br />2x4 I 7x8 WB =
<br />6-2-6 11-4-1
<br />LOADING (psf)
<br />TCLL 20.0
<br />TCDL 7.0
<br />BCLL 0.0
<br />BCDL 10.0
<br />SPACING- 2-0-0
<br />Plate Grip DOL 1.25
<br />Lumber DOL 1.25
<br />Rep Stress Incr NO
<br />Code FBC2020/TP12014
<br />CSI.
<br />TC 0.57
<br />BC 0.35
<br />WB 0.72
<br />Matrix-SH
<br />DEFL. in
<br />Vert(LL) 0.82
<br />Vert(CT) -0.96
<br />Horz(CT) 0.13
<br />(loc) I/defl L/d
<br />16 >625 240
<br />16 >534 180
<br />10 nla n/a
<br />PLATES GRIP
<br />MT20 244/190
<br />Weight: 531 lb FT = 20%
<br />LUMBER- BRACING -
<br />TOP CHORD 2x4 SP No.2 *Except* TOP CHORD
<br />Structural wood sheathing directly applied or 4-4-13 oc purlins.
<br />3-6,6-9: 2x6 SP No.2 BOT CHORD
<br />Rigid ceiling directly applied or 8-1-10 oc bracing.
<br />BOT CHORD 2x6 SP M 26
<br />WEBS 2x4 SP No.3
<br />OTHERS 2x4 SP No.3
<br />REACTIONS. (size) 2=0-3-8, 10=0-3-8
<br />Max Horz 2=94(LC 7)
<br />Max Uplift 2=-1645(LC 8), 10=-1722(LC 8)
<br />Max Grav 2=2532(LC 1), 10=2602(LC 1)
<br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
<br />TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=-8810/5809, 5-6=-11509/7662, 6-7=-11509/7662,
<br />7-8=-8924/5934, 8-9=8926/5936, 9-10=-6152/3976
<br />BOT CHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7061/10896, 16-17=-7061/10896,
<br />15-16=-7123/10952, 13-15=7123/10952, 12-13=3553/5641, 10-12=3554/5625
<br />WEBS 3-20=0/450, 3-19=2515/3773, 4-19=-495/505, 5-19=-2340/1584, 5-17=0/383,
<br />5-16=-539/717, 6-16=-447/498, 7-16=454/644, 7-15=0/383, 7-13=-2267/1515,
<br />8-13=-495/505, 9-13=-2451/3705, 9-12=0/449
<br />NOTES- (11)
<br />1) 2-ply truss to be connected together with IOd (0.131"x3") nails as follows:
<br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.
<br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
<br />This Item has been
<br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
<br />electronically signed and
<br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
<br />sealed by Velez, Joaquin, PE
<br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
<br />3) Unbalanced
<br />using a Digital Signature.
<br />roof live loads have been considered for this design.
<br />4) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; 8=45ft; L=43ft; eave=5ft; Cat.
<br />Printed copies of this
<br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber
<br />document are not considered
<br />DOL=1.60 plate grip DOL=1.60
<br />signed and sealed and the
<br />5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
<br />Signature must be Verified
<br />to the use of this truss component.
<br />6) Provide adequate drainage to prevent water ponding.
<br />On any electronic copies.
<br />7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />Joaquin Velez PE No.69132
<br />8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
<br />)BIek 1— DBA NBTek I $A FL C'-t 6634
<br />will fit between the bottom chord and any other members.
<br />16023 Swhigky Ridge Rd.
<br />9 Provide mechanical connection b others of truss to bearing late capable of withstanding 1645 lb uplift at joint 2 and 1722 lb uplift
<br />(Y ) 9 P p 9 P 1 P
<br />ebe9tereeld. �Jo 63ov
<br />Dare:
<br />at joint 10.
<br />October 27,2023
<br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. i �� ��
<br />Design valid for use only with MiTeM connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd.
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017
<br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com
<br />
|