Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31961918 <br />TTH99-106 <br />T05A <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:31 2023 Page 1 <br />I D: tPuYCeVfQTfyt30 C?ZvfnpzlG U H-RfC?PsB70H q3N SgPgnL8w3u ITXbG KWrC Doi7J4zJ C?f <br />-1-0-Q 8-4-4 15-9-10 21-6-0 27-2-6 34-7-12 43-0-0 <br />f-0 8-41A 7-5-5 5-8-6 I 541-6 7-5 5 8.4-4 <br />Scale = 1:75.1 <br />5.00 F12 5x8 = <br />2x4 11 5x8 = <br />5 17 6 18 19 20 7 <br />3x8 = 15 14 " 13 GD 12 11 3x8 = <br />2x4 11 5x6 = 3x8 = 5x6 = <br />2x4 II <br />8-4-4 15-9-10 <br />21.6-0 <br />27-2 6 <br />347-12 <br />43-0-0 <br />8.4-4 7-5-5 <br />5-8-6 <br />5-8-6 <br />7-5-5 <br />8-4-4 <br />Plate Offsets (X,Y)-- <br />[2:0-4-2,0-1-8],[5:0-5-12,0-2-8],[7:0-5-12,0-2-8],[8:0-0-0,0-0-0],[10:0-4-2,0-1-8],[12:0-3-0,0-3-0],[14:0-3-0,0-3-0] <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. in floc) <br />I/deft Ud <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 1.00 <br />Vert(LL) 0.36 13 <br />>999 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.90 <br />Vert(CT) -0.56 12-13 <br />>918 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.36 <br />Horz(CT) 0.20 10 <br />n/a n/a <br />BCDL 10.0 <br />Code FBC2020/TP12014 <br />Matrix-SH <br />Weight: 220 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. <br />1-4,8-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-4-12 oc bracing. <br />BOT CHORD 2x4 SP No.1 'Except' WEBS 1 Row at midpt <br />3-14, 9-12 <br />12-14: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=221(LC 11) <br />Max Uplift 2=-944(LC 12), 10=857(LC 12) <br />Max Grav 2=1861(LC 17), 10=1807(LC 18) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3889/2054, 3-5=-2974/1694, 5-6=-2884/1753, 6-7=-2884/1753, 7-9=-2975/1694, <br />9-10=3884/2055 <br />BOTCHORD 2-15=1797/3663, 14-15=-1797/3663, 13-14=-1261/2779, 12-13=1249/2675, <br />11-12=-1791/3514, 10-11=1791/3514 <br />WEBS 3-15=0/345, 3-14=-980/593, 5-114=209/669, 5-13=-199/448, 6-13=-337/306, <br />7-13=-196/447, 7-12=-212/672, 9-12=989/600, 9-11=0/346 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; VuK=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 15-9-10, Exterior(2R) <br />15-9-10 to 21-10-9, Interior(1) 21-10-9 to 27-2-6, Exterior(2R) 27-2-6 to 33-3-6, Interior(1) 33-3-6 to 42-10-4 zone; cantilever left and <br />This item has been <br />right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 <br />electronically signed and <br />plate grip DOL=1.60 <br />sealed by Velez, Joaquin, PE <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />using a Digital Signature. <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />Printed Copies of this <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />document are not Considered <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />signed and sealed and the <br />will fit between the bottom chord and any other members, with BCDL = IO.Opsf. <br />signature must be verified <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at <br />joint 10. <br />on any electronic copies. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />mr.qulu X-0- PE So.63182 <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />XHTek L­ DBA N1irek csa Er. Cert 64b4 <br />1602b Saiugles Ridge Rd. <br />Che,(. field. At(-) 6361- <br />Datr: <br />October 27,2023 <br />a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. ■ <br />Design valid for use only with MTek(M connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and propeM damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUT01 Quality Criteria and SB-22 available from Truss Plate Institute (wwwApinst.org) Chesterfield, MO 63017 <br />and BCsi Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com <br />