My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6147-6177 Calle Ochoa St (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6147-6177 Calle Ochoa St (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:13:34 AM
Creation date
2/19/2025 7:54:53 AM
Metadata
Fields
Template:
Building Plans
Street #
6147-6177
Location
Calle Ochoa St
Contractor
Starlight Homes
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31961907 <br />TTH99-106 <br />C3A <br />Jack -Open <br />4 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, <br />-1-0-0 <br />2x4 = <br />8,630 s Aug 30 2023 MiTek Industries, Inc. Thu Oct 26 17:06:12 2023 Page 1 <br />I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3N Sg Pqn L8w3u ITXbGKWrCDoi7J 4zJC?f <br />3-3-10 <br />Scale = 1:13.2 <br />3-3-10 <br />3-3-10 <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. in (loc) I/defl L/d <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.26 <br />Vert(LL) -0.01 2-4 >999 240 <br />MT20 2441190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.11 <br />Vert(CT) -0.01 2-4 >999 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.00 <br />Horz(CT) -0.00 3 n/a n/a <br />BCDL 10.0 <br />Code FBC20201TPI2014 <br />Matrix-P <br />Weight: 12 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc purlins. <br />BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical <br />Max Holz 2=126(LC 12) <br />Max Uplift 3=-80(LC 12), 2=138(LC 12) <br />Max Grav 3=81(LC 17). 2=188(LC 1), 4=62(LC 3) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />NOTES- (7) <br />1) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=oft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 2-0-0, Interior(1) 2-0-0 to 3-2-14 zone; cantilever left <br />and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />5) Refer to girder(s) for truss to truss connections. <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3 and 138 lb uplift at <br />joint 2. <br />7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />JozgWe Velez PE N0.68182 <br />\Biek Luc. DBA NIffe► ESA FL Cert 6634 <br />t60LI Sniugle} Ridge Rd. <br />C'aes[er6eld. k10 63017 <br />lJate: <br />October 27,2023 <br />® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 112/2023 BEFORE USE. ■ <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek". <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SlrrPI1 Quality Criteria and S13-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.