Laserfiche WebLink
Job <br />T uss <br />Truss Type <br />Qty <br />Ply <br />T31961912 <br />TTH99-106 <br />T01 <br />Hip Girder <br />2 <br />Job Reference (optional) <br />tsunaers rlrstbource (I ampa, ry, I ampa, I-L - ssab4, d.bsU s Aug au zuzs m1 I eK Inaustrles, Inc. I nu Uct Zb 1 /:Ub:Z1 zuzs rage 1 <br />I D: tP uYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3NSg Pqn L8w3u ITXbGKWrC Do i7J4zJ C?f <br />1 0 Q 6-2 6 11 4-12 1%5-6 21-6-0 26-6-10 31-7 4 36 9-10 43-0-0 44-0-p <br />-0. 6-2-6 5-2-6 5-0-10 5_ _10 <br />5-0-10 5-0-10 5-2-6 6-2-6 -0- <br />5.00 F12 7x8 = 2x4 II <br />3 21 22 4 23 <br />4x8 = 7x8 = 4x8 = 2x4 II 7x8 = <br />24 5 2526 27 6 28 2930 7 31 32 8 33 34 9 <br />Scale = 1,73.6 <br />5x8 = 20 35 36 19 37 38 1817 39 40 16 41 42 1514 43 44 13 45 46 12 5x8 = <br />2x4 11 5x8 = 7x8 WB = 4x8 = 2x4 11 5x8 = 2x4 11 <br />2x4 I 7x8 WB = <br />Hi 111-12 16-5-6 21-6-0 26-6-10 31-7-4 36-9-10 434-0 <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr NO <br />Code FBC2020/TP12014 <br />CSI. <br />TC 0.57 <br />BC 0.35 <br />WB 0.72 <br />Matrix-SH <br />DEFL. in <br />Vert(LL) 0.82 <br />Vert(CT) -0.96 <br />Horz(CT) 0.13 <br />(loc) I/defl Ud <br />16 >625 240 <br />16 >534 180 <br />10 n/a n/a <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 531 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 *Except* TOP CHORD <br />Structural wood sheathing directly applied or 4-4-13 oc purlins. <br />3-6,6-9: 2x6 SP No.2 BOT CHORD <br />Rigid ceiling directly applied or 8-1-10 oc bracing. <br />BOT CHORD 2x6 SP M 26 <br />WEBS 2x4 SP No.3 <br />OTHERS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=94(LC 7) <br />Max Uplift 2=-1645(LC 8), 10=-1722(LC 8) <br />Max Grav 2=2532(LC 1), 10=2602(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=-8810/5809, 5-6=11509/7662, 6-7=-11509/7662, <br />7-8=-8924/5934, 8-9=-8926/5936, 9-10=-6152/3976 <br />BOTCHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7061/10896, 16-17=7061/10896, <br />15-16=-7123/10952, 13-15=7123/10952, 12-13=3553/5641, 10-12=-3554/5625 <br />WEBS 3-20=0/450, 3-19=-2515/3773, 4-19=-495/505, 5-19=-2340/1584, 5-17=0/383, <br />5-16=-539/717, 6-16=-447/498, 7-16=-454/644, 7-15=0/383, 7-13=-2267/1515, <br />8-13=-495/505, 9-13=-2451/3705, 9-12=01449 <br />NOTES- (11) <br />1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: <br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. <br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. <br />This Item has been <br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. <br />electronically signed and <br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to <br />sealed by Velez, Joaquin, PE <br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. <br />using a Digital Signature. <br />3) Unbalanced roof live loads have been considered for this design. <br />4) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />Printed copies of this <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber <br />document are not considered <br />DOL=1.60 plate grip DOL=1.60 <br />signed and sealed and the <br />5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />signature must be verified <br />to the use of this truss component. <br />6) Provide adequate drainage to prevent water ponding. <br />On any electronic copies. <br />7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />ao.gtda Velez PE xo.d9182 <br />8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />lfirek L— DBA .ilirek tSA. FL Ceti 4634 <br />will fit between the bottom chord and any other members. <br />16023 Single} Ridge Rd. <br />ce�esrerreld. �1a 301', <br />9 Provide mechanical connection b others of truss to bearing late capable of withstanding 1645 lb uplift at 2 and 1722 lb uplift <br />(y ) 9 P P 9 P J P <br />nsie: <br />at joint 10. <br />October 27,2023 <br />® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2r2023 BEFORE USE. MiTek" <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and properly damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Qual ty Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com <br />