Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31683325 <br />TTH81-89 <br />T10 <br />Common <br />42 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Wed Sep 27 10:36:10 2023 Page 1 <br />ID:tPuYCeVfQTfYt30C?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3uITXbGKWrCDoi7J4zJC?f <br />�1-04 <br />7-7-3 14-6-4 21-6-0 28-5-12 35-4-13 43-0-0 44-0-p <br />-0 7-7-3 6-11-1 6-11-12 6-11-12 6-11-1 7-7-3 <br />d <br />5x6 = <br />5.00 F12 <br />Scale = 1:72.2 <br />3x8 = ., « .o -- 11 11 .1 — — — 11 3x8 = <br />8-1 <br />3x4 = <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />YES <br />BCDL <br />10.0 <br />Code FBC2020/TP12014 <br />LUMBER - <br />TOP CHORD 2x4 SP No.2 *Except` <br />1-4,8-11: 2x4 SP No.1 <br />BOT CHORD 2x4 SP No.1 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=298(LC 11) <br />Max Uplift 2=-943(LC 12), 10=943(LC 12) <br />Max Grav 2=1885(LC 17), 10=1885(LC 18) <br />4x6 = 3x4 = 3x4 = <br />3x4 = 4x6 = <br />25-8-1 34-0-2 , <br />CSI. <br />DEFL. in floc) I/dell L/d <br />PLATES GRIP <br />TC 0.91 <br />Vert(LL)-0.4014-15 >999 240 <br />MT20 244/190 <br />BC 0.91 <br />Vert(CT) -0.68 14-15 >754 180 <br />WB 0.99 <br />Horz(CT) 0.18 10 n/a n/a <br />Matrix-SH <br />Weight: 218 lb FT = 20% <br />BRACING - <br />TOP CHORD Structural wood sheathing directly applied. <br />BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3933/2001, 3-5=-3807/2013, 5-6=2890/1660, 6-7=2890/1660, 7-9=-3808/2013, <br />9-10=-3933/2001 <br />BOT CHORD 2-17=-1707/3785,15-17=-1308/3022,14-15=-850/2218,12-14=-1309/2875, <br />10-12=-1708/3561 <br />WEBS 6-14=-518/1152, 7-14=-763/574, 7-12=393/911, 9-112=360/364, 6-15=-518/1152, <br />5-15=-763/574, 5-17=-393/910, 3-17=360/364 <br />NOTES- (7) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) <br />21-6-0 to 25-9-10, Interior(1) 25-9-10 to 44-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for <br />members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) <br />2=943, 10=943. <br />7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Jeagrdn Velez PE \0.68182 <br />.NBTek [uc. DBA 31iTek USA FL Cen 6634 <br />16023 Saiuglep Ridge Rd. <br />Chesterfield. -MO 63017 <br />Date: <br />September 28,2023 <br />O WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. l/2/2023 BEFORE USE. <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />MiTe <br />k <br />a truss system. Before use, the building designer must verily the applicability of design parameters and property incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see A SUTPII Quality Criteria and SB-22 available from Truss Plate Institute (www.tpinst.org) <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) <br />16023 Swingley Ridge Rd. <br />Chesterfield, MO 63017 <br />314.434.1200 / MTek-US.com <br />