Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />City <br />Ply <br />T31683327 <br />TTH81-89 <br />T11 <br />Common <br />4 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Aug 30 2023 MiTek Industries, Inc. Wed Sep 27 10:36:12 2023 Page 1 <br />I D:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?P s B7OHg3N SgPgn L8w3u ITXbGKWrC Doi7J4zJC?f <br />1 0 Q 7-7-3 14-6-10 21-6-0 28 5 6 35-4-13 43-0-0 45-0-0 <br />7-7-3 6-11-6 6-11 6 6-11, 6-11-6 7-7-3 + 2-0-0 <br />5x6 = <br />5.00 12 <br />Scale = 1:73.7 <br />1Ij <br />3x4 = 4x6 = <br />3x4 = <br />3x4 = 3x4 = <br />4x6 = <br />8-11-14 17-3-15 25-8-1 <br />34-0-2 43-0-0 <br />8-11-14 8-4-1 I 8-4-1 <br />84-1 8-11-14 <br />Plate Offsets (X,Y)— [2:0-4-2,0-1-8], [4:0-3-0,Edge], [8:0-3-0,Edge], [10:0-4-2,D-1-8] <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. <br />in (loc) Udefl L/d <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.91 <br />Vert(LL) -0.40 14-15 >999 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.91 <br />Vert(CT) -0.68 14-15 >757 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.99 <br />Horz(CT) <br />0.18 10 n/a n/a <br />BCDL 10.0 <br />Code FBC20201TPI20114 <br />Matrix-SH <br />Weight: 220 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 *Except` TOP CHORD <br />Structural wood sheathing directly applied. <br />1-4,8-11: 2x4 SP No.1 BOT CHORD <br />Rigid ceiling directly applied or 4-8-6 oc bracing. <br />BOT CHORD 2x4 SP No.1 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=31 O(LC 10) <br />Max Uplift 2=939(1-C 12), 10=1020(LC 12) <br />Max Grav 2=1885(LC 17), 10=1934(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3932/1997, 3-5=3806/2010, 5-6=2887/1656, 6-7=2886/1647, 7-9=3785/1971, <br />9-10=-3923/1959 <br />BOT CHORD 2-17=-1668/3792,15-17=-1252/3027,14-15=-827/2225,12-14=-1281/2869, <br />10-12=-1668/3537 <br />WEBS 6-14=-516/1150, 7-14=-757/569, 7-112=362/894, 9-12=354/345, 6-15=519/1153, <br />5-15=763/575, 5-17=-395/913, 3-17=361/365 <br />NOTES- (7) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6.0, Exterior(2R) <br />21-6-0 to 25-9-10, Interior(1) 25-9-10 to 45-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for <br />members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />This item has been <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />electronically signed and <br />to the use of this truss component. <br />sealed by Velez, Joaquin, PE <br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />` <br />using a Digital Signature. <br />5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-&0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />Printed Copies of this <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) <br />document are not considered <br />2=939,10=1020. <br />'This <br />signed and sealed and the <br />7) manufactured product is designed as an individual building component. The suitability and use of this component for any <br />signature must be verified <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />on any electronic copies. <br />' <br />3-card. Velez PE N..68I82 <br />\Diek Inc. DBA 381fek USA FL Cert 6634 <br />16023 Swingiep Ridge Rd. <br />Chesterfield. MO 63017 <br />Dale: <br />September 28,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 112/2023 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury antl ppropperrtyty damagQe. For general quid - regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIV, Quality Cdteda and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 1 MTek-US.com <br />