Job
<br />Truss
<br />Truss Type
<br />Qty
<br />Ply
<br />T31683313
<br />TTH81-89
<br />T01
<br />Hip Girder
<br />2
<br />Job Reference (optional)
<br />6utlders FtrstSource (I ampa, FL), I ampa, FL - 33564, 8.630 s Aug 30 2023 Mi Fek Industries, Inc. Wed Sep 2/ 10:35:55 2023 Page 2
<br />I D:tPUYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?P sB70Hg3NSgPgn L8w3u ITXbG KWrCDoi7J4zJ C?f
<br />NOTES- (11)
<br />10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 124 lb down and 158 lb up at 6-2-6, 125 lb down and 153 lb up at
<br />8-3-2, 125 lb down and 153 lb up at 10-3-2, 124 lb down and 153 lb up at 12-3-2, 124 lb down and 153 lb up at 14-3-2, 124 lb down and 153 lb up at 16-3-2, 124 lb
<br />down and 153 lb up at 18-3-2, 124 lb down and 153 lb up at 20-3-2, 124 lb down and 153 lb up at 21-6-0, 124 lb down and 153 lb up at 22-8-14, 124 lb down and 153 lb
<br />up at 24-8-14, 124 lb down and 153 lb up at 26-8-14, 124 lb down and 153 lb up at 28-8-14, 124 lb down and 153 lb up at 30-8-14, 125 lb down and 153 lb up at
<br />32-8-14, and 125 lb down and 153 lb up at 34-8-14, and 225 lb down and 372 lb up at 36-9-10 on top chord, and 141 lb down at 6-2-6, 56 lb down at 8-3-2, 56 lb down
<br />at 10-3-2, 56 lb down at 12-3-2, 56 lb down at 14-3-2, 56 lb down at 16-3-2, 56 lb down at 18-3-2, 56 lb down at 20-3-2, 56 lb down at 21-6-0, 56 lb down at 22-8-14,
<br />56 lb down at 24-8-14, 56 lb down at 26-8-14, 56 lb down at 28-8-14, 56 lb down at 30-8-14, 56 lb down at 32-8-14, and 56 lb down at 34-8-14, and 141 lb down at
<br />36-8-14 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
<br />11) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of
<br />the building designer per ANSI TPI 1 as referenced by the building code."
<br />LOAD CASE(S) Standard
<br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
<br />Uniform Loads (plf)
<br />Vert: 1-3=54, 3-9=54, 9-11=54, 2-10=-20
<br />Concentrated Loads (lb)
<br />Vert: 3=-68(B) 9=-167(B) 20=-88(B) 5=68(B) 17=-28(8) 16=-28(B) 6=-68(B) 15=28(B) 7=68(B) 12=-88(B) 21=-68(B) 22=-68(B) 23=68(B) 24=-68(B) 25=-68(B)
<br />27=-68(B) 28=-68(B) 30=68(131) 31=-68(B) 32=-68(B) 33=-68(B) 34=-68(8) 35=28(B) 36=-28(B) 37=-28(B) 38=-28(B) 39=28(B) 40=-28(B) 41=-28(B) 42=-28(B)
<br />43=28(B) 44=-28(B) 45=28(B) 46=28(B)
<br />WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />i
<br />��
<br />�®
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and ppropperrtyry damagge. For general guidance regarding the
<br />16023 Swingley Ridge Rd.
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7Rl1 Quaiity Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org)
<br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com)
<br />Chesterfield, MO 63017
<br />314.434.12001 MTek-US.com
<br />
|