My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6186-6910 Calle Ochoa St (2)
Zephyrhills
>
Building Department
>
Building Plans
>
6186-6910 Calle Ochoa St (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2025 10:19:25 AM
Creation date
2/19/2025 7:55:53 AM
Metadata
Fields
Template:
Building Plans
Street #
6186-6910
Location
Calle Ochoa St
Contractor
Starlight Homes
Building Plans - Permit #
6182-6909
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31406292 <br />TTH47-55 <br />T03 <br />Hip <br />2 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Jul 28 2023 MiTek Industries, Inc. Thu Aug 24 12:30:48 2023 Page 1 <br />I D: tPuYCeVfQTfYt3OC?ZvfnpzlG U H-RfC?PsB7OHg3N SgPgnL8w3u ITXbG K WrC Doi7J4zJ C?f <br />-1-0-Q 6�-5 + 11-0-0 18-0-9 24-11-7 32-0-0 36-5-11 43-0-0 4p-0-0 <br />-0- 6.6-5 4-5-11 7-0-9 6.10-13 7-0-9 4-5-11 6-6-5 -0- <br />5.00 12 <br />5x8 = 2x4 11 4x6 = 3x8 = 5x6 = <br />4 22 23 5 24 6 25 7 26 827 <br />Scale = 1:73.7 <br />US 19 18 17 16 15 14 13 12 US <br />2x4 11 3x4 = 4x6 _ 3x10 = 2x4 11 5x6 = 3x8 = 2x4 11 <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />YES <br />BCDL <br />10.0 <br />Code FBC2020/TPI2014 <br />LUMBER - <br />TOP CHORD <br />2x4 SP No.2 *Except* <br />4-6: 2x4 SP No.1 <br />BOT CHORD <br />2x4 SP No.2 <br />WEBS <br />2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=159(LC 11) <br />Max Uplift 2=-943(LC 12), 10=-943(LC 12) <br />Max Grav 2=1642(LC 1). 10=1642(LC 1) <br />CSI. <br />DEFL. <br />in (loc) I/defl L/d <br />PLATES GRIP <br />TC 0.90 <br />Vert(LL) <br />0.52 15-16 >982 240 <br />MT20 244/190 <br />BC 0.94 <br />Vert(CT) <br />-0.74 15-16 >694 180 <br />WB 0.75 <br />Horz(CT) <br />0.23 10 n/a n/a <br />Matrix-SH <br />Weight: 218 lb FT = 20% <br />BRACING - <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />BOT CHORD <br />Rigid ceiling directly applied or 2-2-0 oc bracing. <br />WEBS <br />1 Row at midpt 7-16, 7-13 <br />FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3513/2077, 3-4=-3065/1877, 4-5=-3607/2258, 5-7=3607/2259, 7-8=-2810/1793, <br />8-9=-3066/1877,9-10=-3512/2077 <br />BOT CHORD 2-19=-1794/3166, 18-19=-1794/3166, 16-18=-1479/2792, 15-16=1949/3606, <br />13-15=-1949/3606, 12-13=1806/3165, 10-112=1806/3165 <br />WEBS 3-18=-476/379, 4-18=-161/394, 4-16=-577/1077, 5-16=397/373, 7-15=01281, <br />7-13=-1059/569, 8-13=-460/879, 9-13=-474/379 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vuft=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 11-D-0, Exterior(2R) <br />11-0-0 to 17-1-0, Interior(1) 17-1-0 to 32-0-0, Exterior(2R) 32-0-0 to 38-1-0, Interior(1) 38-1-0 to 44-D-0 zone; cantilever left and right <br />exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate <br />grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at <br />joint 10. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Joaquin Velez PE \0.68182 <br />JBTek Luc. DBA.iBTek GSA FL C-t 6634 <br />16023 Swingley Ridge Rd. <br />Ctiesterfleld, MO 63017 <br />Date: <br />August 25,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. MiTek" <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and propertrtyy damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTTit Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MiTek-US.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.