Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31406300 <br />TTH47-55 <br />T07A <br />HIP <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSouroe (Tampa, FL), Tampa, FL - 33564, 8.630 s Jul 28 2023 MiTek Industries, Inc. Thu Aug 24 12:30:59 2023 Page 1 <br />I D:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3ulTXbGKWrCDoi7J4zJC?f <br />-1-0-p 7-0-1 13-0-0 19-1-8 23-10-8 30-0-0 35-11-15 43-0-0 <br />7-0-1 5-11-15 6-1-8 4-9-0 6-1-8 1-1-1 1-1 7-0-1 <br />Scale = 1:75.1 <br />d <br />5x6 = <br />5.00 12 <br />5x8 = <br />3x8 = .r 1. 11 10 15 « 14 - - - .1 3x8 = <br />3x4 = 5x6 WB = 3x8 = <br />3x4 = 5x6 WB = <br />3x4 = <br />9-10-15 19-1-8 23-10-8 33-1-1 43-0-0 <br />9-10-15 9-2-9 4-9-0 + 9-2-9 9-10-15 <br />Plate Offsets (X,Y)-[2:0-4-2,0-1-8],[6:0-3-0,0-2-4],[7:0-5-12,0-2-8],[11:0-4-2,0-1-8] <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />CSI. <br />TCLL <br />20.0 <br />Plate Grip DOL <br />1.25 <br />TC 0.75 <br />TCDL <br />7.0 <br />Lumber DOL <br />1.25 <br />BC 0.96 <br />BCLL <br />0.0 <br />Rep Stress Incr <br />YES <br />WB 0.41 <br />BCDL <br />10.0 <br />Code FBC2020ITP12014 <br />Matrix-SH <br />LUMBER - <br />TOP CHORD <br />2x4 SP No.2 *Except* <br />1-4,9-11: 2x4 SP No.1 <br />BOT CHORD <br />2x4 SP 285OF 2.0E or 2x4 SP M 31 *Except* <br />13-16: 2x4 SP No.2 <br />WEBS <br />2x4 SP No.3 <br />OTHERS <br />2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 11=0-3-8 <br />DEFL. in floc) I/defl L/d <br />Vert(LL) -0.40 12-14 >999 240 <br />Vert(CT) -0.70 12-14 >729 180 <br />Horz(CT) 0.17 11 n/a n/a <br />PLATES GRIP <br />MT20 2441190 <br />Weight: 227 lb FT = 20% <br />BRACING - <br />TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. <br />BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. <br />WEBS 1 Row at midpt 5-15, 7-15, 8-14 <br />Max Horz 2=265(LC 11) <br />Max Uplift 2=-944(LC 12), 11=-857(LC 12) <br />Max Grav 2=1871(LC 17), 11=1819(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3900/2055, 3-5=-3656/1944, 5-6=2629/1554, 6-7=2389/1507, 7-8=2633/1549, <br />8-10=-3669/1950, 10-11=-3914/2074 <br />BOT CHORD 2-17=-1808/3727, 15-17=-1466/3104, 14-15=-1038/2387, 12-14=-1455/2952, <br />11-12=-1805/3550 <br />WEBS 3-17=-351/346, 5-17=-214/750, 5-15=877/557, 6-15=-331/763, 7-14=-327/837, <br />8-14=-881/560, 8-12=-238/757, 10-12=-354/365 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; VuIt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Extedor(2E) <br />This item has been <br />19-1-8 to 23-10-8, Exterior(2R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 42-10-4 zone; cantilever left and right exposed ; end vertical <br />electronically signed and <br />left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />sealed by Velez, Joaquin, PE <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements speck <br />using a Digital Signature. <br />to the use of this truss component. <br />4) Provide adequate drainage to prevent water ponding. <br />Printed Copies Of this <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />document are not considered <br />6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />signed and sealed and the <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />SI g nature must be verified <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 944 lb uplift at joint 2 and 857 lb uplift at <br />joint 11. <br />on any electronic Copies. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />Jeagohi Velez PH Ne.68182 <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />WTek 1- DBA.A11Tek csA FL Cert 6Q4 <br />16023 Sniogley Ridge Rd. <br />Cbest-fMd. MO 63017 <br />Date: <br />August 25,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/212023 BEFORE USE. Design valid for use ony with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek" <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chard members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIlT11 Quality Criteria and DSB-22 available from Truss Plate institute (www.tpinst.org) Chesterfield, MO 63017 <br />and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com <br />