Laserfiche WebLink
Job <br />Truss <br />City <br />PlyT31406303 <br />TTH4755 <br />T1OA <br />rCrussMType <br />N <br />19 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Jul 28 2023 MiTek Industries, Inc. Thu Aug 24 12:31:04 2023 Page 1 <br />I D: tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSg Pqn L8w3u ITXbGKWrC Doi7J4zJC?f <br />i1-0-Q 7-7-3 14-6-4 21-6-0 28-5-12 35-4-13 43-0-0 <br />7-7-3 6-11-1 6-11-12 6-11-12 6-11-1 7-7-3 <br />5x6 = <br />5.00 F12 <br />Scale = 1:72.2 <br />3x8 = io ci w -- — — - i< <n co 11 3x8 = <br />3x4 = 4x6 = <br />3x4 = <br />3x4 = <br />4x6 = <br />3x4 = <br />Io <br />8-11-14 17-3-15 <br />25-8-1 <br />34-0-2 43-0-0 <br />8-11-14 8-4-1 <br />8-4-1 <br />B-4-1 8-11-14 <br />Plate Offsets X,Y)— [2:0-4-2,0-1-8], [4:0-3-0,Edge], [8:0-3-0,Edge], [10:0-4-2,0-1-8] <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. <br />in (loc) I/defl L/d <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.94 <br />Vert(LL) <br />-0.40 13-14 >999 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.93 <br />Vert(CT) <br />-0.68 13-14 >752 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.99 <br />Horz(CT) <br />0.18 10 n/a n/a <br />BCDL 10.0 <br />Code FBC2020/TP12014 <br />Matrix-SH <br />Weight: 216 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 'Except` <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />1-4,8-10: 2x4 SP No.1 <br />BOT CHORD <br />Rigid ceiling directly applied or 2-2-0 oc bracing. <br />BOT CHORD 2x4 SP No.1 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=297(LC 11) <br />Max Uplift 2=-944(LC 12), 10=857(LC 12) <br />Max Grav 2=1886(LC 17), 10=1831(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3934/2003, 3-5=3808/2015, 5-6=2892/1661, 6-7=2892/1670, 7-9=3817/2052, <br />9-10=-3943/2040 <br />BOT CHORD 2-16=-1751/3777, 14-16=-1352/3015, 13-14=-894/2210, 11-13=-1329/2875, <br />10-11=-1767/3572 <br />WEBS 6-13=-519/1154, 7-13=-765/576, 7-11=424/918, 9.11=363/380, 6-14=-519/1152, <br />5-14=-763/574, 5-16=-393/910, 3-16=-360/363 <br />NOTES- (7) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-D-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) <br />21-6-0 to 25-9-10, Interior(1) 25-9-10 to 42-10-4 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for <br />members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />This item has been <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />electronically signed and <br />to the use of this truss component. <br />sealed by Velez, Joaquin, PE <br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />' <br />using a Digital Signature. <br />5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = IO.Opsf. <br />Printed copies of this <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) except (jt=lb) <br />document are not considered <br />2=944, 10=857. <br />'This <br />signed and sealed and the <br />7) manufactured product is designed as an individual building component. The suitability and use of this component for any <br />signature must be verified <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />on any electronic copies. <br />Joegnin Yelez PE No.68182 <br />Niiek Iae. DBA MITek USA FL Cert6634 <br />16023 Sningtey Ridge Rd. <br />Chesterfield, 1,30 63017 <br />Date: <br />August 25,2023 <br />A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 11212023 BEFORE USE. Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTek' <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and propertrtyy damage. For general guidance regartling the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/frll Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and SCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.12001 MiTek-US.com <br />