Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T31683313 <br />TTH72-80 <br />T01 <br />Hip Girder <br />2 <br />n <br />L <br />Job Reference (optional) <br />ounaers rirsioource t I ampa, I -Li, I ampa, rL - aa004, o.odu s Hug aU zuza m1I eK Inausmes, Inc. vvea aep zr-iu:do:ob zuza rage i <br />ID: tPuYCeVfQTfYt3OC?ZvfnpzlGU H-RfC?PsB7OHg3NSgPgnL8w3uITXbGKWrCDoi7J4zJC?f <br />-�1-0-Q 6-2-6 11-4-12 11 Ill 21-6-0 26-6-10 31-7-4 36-9-10 43-0-0 4,4-0-p <br />1-0 d 6-21 5-2-0 5 0 10 5-0-10 5-0-10 5 0 10 5-2Fi 6-2 6 <br />5.00 12 6x8 = 2x4 11 4x8 = 7x8 = 4xB = <br />3 21 22 4 23 24 5 2526 27 6 28 2930 7 31 <br />2x4 11 6xB = <br />32 8 33 34 9 <br />Scale = 1:73.6 <br />5x8 = 20 35 36 19 37 38 1817 39 40 16 41 42 1514 43 44 t3 45 46 12 5x8 = <br />2x4 11 5x8 = 7x8 WB = 4x8 = 2x4 11 5x8 = 2x4 11 <br />2x4 I I 7x8 WB = <br />12: 11-4-12 16-5-6 21-0-0 26E-10 31-7-4 36-NO 43-0-0 <br />6-2-6 5 5-0-10 5-0-t0 5-0-10 5-0-10 5-2-6 6-2. <br />LOADING (psf) <br />SPACING- <br />2-0-0 <br />CSI. <br />DEFL. <br />in <br />(loc) <br />I/deft <br />Ud <br />TCLL 20.0 <br />Plate Grip DOL <br />1.25 <br />TC 0.57 <br />Vert(LL) <br />0.82 <br />16 <br />>625 <br />240 <br />TCDL 7.0 <br />Lumber DOL <br />1.25 <br />BC 0.35 <br />Vert(CT) <br />-0.96 <br />16 <br />>534 <br />180 <br />BCLL 0.0 <br />Rep Stress Incr <br />NO <br />WB 0.72 <br />Horz(CT) <br />0.13 <br />10 <br />n/a <br />n/a <br />BCDL 10.0 <br />Code FBC2020/TP12014 <br />Matrix-SH <br />LUMBER - <br />TOP CHORD <br />2x4 SP No.2 "Except" <br />3-6,6-9: 2x6 SP No.2 <br />BOT CHORD <br />2x6 SP M 26 <br />WEBS <br />2x4 SP No.3 <br />OTHERS <br />2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=-94(LC 23) <br />Max Uplift 2=-1645(LC 8), 10=1722(1_C 8) <br />Max Grav 2=2532(LC 1), 10=2602(LC 1) <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 531 lb FT = 20% <br />BRACING - <br />TOP CHORD Structural wood sheathing directly applied or 4-4-13 oc purlins. <br />BOT CHORD Rigid ceiling directly applied or 8-1-10 oc bracing. <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-5972/3778, 3-4=-8812/5811, 4-5=-8810/5809, 5-6=11509/7662, 6-7=11509/7662, <br />7-8=-8924/5934, 8-9=-8926/5936, 9-10=-6152/3976 <br />BOT CHORD 2-20=-3371/5458, 19-20=-3370/5475, 17-19=-7060/10896, 16-17=7060/10896, <br />15-16=-7123/10952, 13-15=-7123/10952, 12-13=-3553/5641, 10-12=-3554/5625 <br />WEBS 3-20=0/450, 3-19=2515/3773, 4-19=-495/505, 5-19=-2340/1584, 5-17=0/383, <br />5-16=-539/717, 6-16=-447/498, 7-16=-454/644, 7-15=0/383, 7-13=-2267/1515, <br />8-13=-495/505, 9-13=-2451/3705, 9-12=0/449 <br />NOTES- (11) <br />1) 2-ply truss to be connected together with 1 Od (0.131 "x3") nails as follows: <br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. <br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. <br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. <br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to <br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. <br />3) Unbalanced roof live loads have been considered for this design. <br />4) Wind: ASCE 7-16; Vult=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; Lumber <br />DOL=1.60 plate grip DOL=1.60 <br />5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />6) Provide adequate drainage to prevent water ponding. <br />7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />8) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fd between the bottom chord and any other members. <br />9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1645 lb uplift at joint 2 and 1722 lb uplift <br />at joint 10. <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />JoogWn Velez PE Ne.68192 <br />1Diek [ac. DBA kBIek G8A FL Cert 6634 <br />16023 Swiattky Ridge Rd. <br />Chesterfield. NIO 63017 <br />Date: <br />September 28,2023 <br />A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. MiTek"' <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall <br />building tlesign. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrrPl1 Quality Criteria and DSS-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com <br />