Job <br />Truss <br />Type <br />Qty <br />Ply <br />FTr.uls.sl <br />T30256141 <br />TTH23-26 <br />V03 <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8.630 s Nov 19 2022 MiTek Industries, Inc. Thu Apr 6 08:43:57 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGU H-eMLysk31 aKWFgS4fLYpoOA8yRpj3mLu3NFEgNkzTUj W <br />2-0-0 4-0-0 <br />2-0-0 2-0-0 <br />3x6 = Scale = 11A <br />5.00 12 2 <br />3 <br />1 <br />0 0 <br />2x4 <br />2x4 <br />0 Q-f0 4-M <br />0 0 3-11-6 <br />Plate Offsets (X,Y)-- 12:0-3-0,Edge] <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. in floc) I/defl L/d <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.08 <br />Vert(LL) n/a n/a 999 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.12 <br />Vert(CT) n/a n/a 999 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.00 <br />Horz(CT) -0.00 3 rile n/a <br />BCDL 10.0 <br />Code FBC2020/TPI2014 <br />Matrix-P <br />Weight: 10 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. <br />BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />REACTIONS. (size) 1=3-10-13, 3=3-10-13 <br />Max Horz 1=-14(LC 10) <br />Max Uplift 1=-50(LC 12), 3=-50(LC 12) <br />Max Grav 1=92(LC 1), 3=92(LC 1) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; Vutt=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=30ft; eave=4ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; cantilever left and right exposed ; end vertical left and <br />right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />4) Gable requires continuous bottom chord bearing. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />This item has been <br />electronically signed and <br />sealed by Velez, Joaquin, PE <br />using a Digital Signature. <br />Printed copies of this <br />document are not considered <br />signed and sealed and the <br />signature must be verified <br />on any electronic copies. <br />Joaquin Velez PE No.68182 <br />MiTek lua. DRA NDTek GSA FL CcM 6rr34 <br />161 Swtuid.y Ridge Rd. <br />Cheste 1116d.1,106M17 <br />Date: <br />April 7,2023 <br />A WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPII Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd <br />Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 <br />