Laserfiche WebLink
Addendum No. 01 Revision No. 1 Narrative <br />Project Name: FH Zephyrhills Ed Expansion & Ortho Renovation <br />Project No.: H-15027.00 <br />Dwg No <br />b6d ion ` W <br />Remarks <br />Reason for -thane ` <br />M212 <br />DUCTWORK PLAN - LEVEL 1 - <br />PHASE 2 <br />Revised ductwork. <br />Owner Changes <br />M222 <br />DUCTWORK PLAN - LEVEL 2 - AREA <br />2 <br />Revised ductwork. <br />Coordination <br />M231 <br />DUCTWORK PLAN - LEVEL 3 - AREA <br />1 <br />Revised DDC panel location. <br />Coordination <br />M232 <br />DUCTWORK PLAN - LEVEL 3 - AREA <br />2 <br />Added keynote for alternate pipe <br />routing. <br />Coordination <br />M322 <br />PIPING PLAN - LEVEL 2 - AREA 2 <br />Added keynote for alternate pipe <br />routin . <br />Coordination <br />M501 <br />MECHANICAL SCHEDULES <br />Revised schedules. <br />Owner Changes <br />M701 <br />MECHANICAL CONTROLS <br />Revised RTU controls. <br />Coordination <br />Electrical Drawings <br />Dwg No: <br />description <br />Remarks <br />Reason forJC11,ar4ge , <br />E002 <br />ELECTRICAL ONE -LINE DIAGRAM <br />Added shunt trip for elevator <br />Coordination <br />El 12 <br />ELECTRICAL DEMOLITION PLAN - <br />LEVEL 1 - PHASE 2 <br />Showing demolished lights <br />Coordination <br />E120 <br />OVERALL ELECTRICAL PLAN - LEVEL <br />2 <br />Clarified panel names <br />Coordination <br />E211 <br />POWER PLAN - LEVEL 1 - PHASE 1 <br />Adjusted power <br />Coordination <br />E212 <br />POWER PLAN - LEVEL 1 - PHASE 2 <br />Adjusted power <br />Coordination <br />E311 <br />LIGHTING PLAN - LEVEL 1 - PHASE 1 <br />Added lighting <br />Owner changes <br />E312 <br />LIGHTING PLAN - LEVEL 1 - PHASE 2 <br />Added lighting <br />Owner changes <br />E321 <br />LIGHTING PLAN - LEVEL 1 - PHASE 1 <br />Added lighting <br />Coordination <br />E322 <br />LIGHTING PLAN - LEVEL 2 - PHASE 2 <br />Added lighting <br />Coordination <br />E41 1 <br />FIRE ALARM PLAN - LEVEL 1 - <br />PHASE 1 <br />Adjusted fire alarm <br />Coordination <br />E412 <br />FIRE ALARM PLAN - LEVEL 1 - <br />PHASE 2 <br />Adjusted fire alarm <br />Coordination <br />E512 <br />NURSE CALL PLAN - LEVEL 1 - <br />PHASE 2 <br />Adjusted nurse call <br />Coordination <br />E601 <br />ELECTRICAL DETAILS <br />Coordination <br />E701 <br />ENLARGED TYPICAL ROOMS <br />Adjusted switching <br />Coordination <br />E702 <br />ENLARGED COMMUNICATIONS & <br />ELECTRICAL ROOMS <br />Moved DDC and CTU <br />Coordination <br />E801 <br />PANEL SCHEDULE NORMAL <br />BRANCH <br />Added circuit for cove lighting <br />Coordination <br />E804 <br />PANEL SCHEDULE CRITICAL <br />BRANCH <br />Removed circuits, added spares <br />Coordination <br />800 North Magnolia Avenue ■ Suite 600 ■ Orlando, Florida 32803 ■ 407.839.0886 ■ www.huntonbrady.com ■ #AAC001744 <br />