Laserfiche WebLink
Job <br />cuss <br />Truss Type <br />Qty <br />Ply <br />Dupont <br />T20455631 <br />772591-X <br />[A13 <br />Hip <br />1 I1 <br />Job Reference(optional) <br />American Builder Supply, Sanford, FL 8.330 s May 6 2020 MiTek Industries, Inc. Fri Jun 12 13:48:37 2020 Page 1 <br />ID: RWGiORDIF509gYXBdOupOozldd5-qR WB7LOmnGGWY5ZX7LhXJEdFPrn4nilOXV73iz7?tu <br />16-22 5 22-6-1 29-8-0 g2211-5 3B-8-0 3 8- <br />5 811 3 3 5 7-2-15 6-3 2 7-1-15 3 3 5 5-8-11 0 0 <br />5.00 12 <br />5x6 = <br />3x4 = <br />23 24 25 5 <br />5x6 = <br />26 27 <br />5x6 = <br />287 <br />Scale = 1:69.9 <br />Ia <br />3x6 = <br />14 13 12 11 <br />5x10 = <br />3x4 = 3x8 MT20HS = <br />3x8 = <br />3x8 = <br />LOADING (psi) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 ' <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2017/TPI2014 <br />CSI. <br />TC 0.68 <br />BC 0.70 <br />WB 0.41 <br />Matrix -AS <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in (loc) Udefl L/d <br />-0.33 13 >999 360 <br />-0.69 13-14 >671 240 <br />0.16 9 n/a n/a <br />0.44 13 >999 240 <br />PLATES <br />MT20 <br />MT20HS <br />Weight: 180 lb <br />GRIP <br />2441190 <br />1871143 <br />FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />BOT CHORD 2x4 SP M 30 <br />BOT CHORD <br />Rigid ceiling directly applied. <br />WEBS 2x4 SP No.3 <br />WEBS <br />1 Row at midpt 5-14, 6-11 <br />REACTIONS. (size) 2=0-8-0, 9=0-8-0 <br />Max Horz 2=-155(LC 10) <br />Max Uplift 2=716(LC 12), 9=716(LC 12) <br />Max Grav 2=1485(LC 1), 9=1485(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3156/1984, 3-4=-2926/1806, 4-5=267011720, 5-6=3662/2233, 6-7=2691/1729, <br />7-8=-2914/1800,8-9=-3153/1986 <br />BOT CHORD 2-14=-1720/2881, 13-14=-2010/3580, 11-13=-2002/3574, 9-11 =-1 729/2878 <br />WEBS 3-14=-3041349, 4-14=-386/829, 5-14=1121/709, 5-13=0/269, 6-13=0/271, <br />6-11=-1095/698, 7-11=-386/829, 8-11=312/353 <br />NOTES- <br />1) Unbalanced roof live loads have been considered for this design <br />2) Wind: ASCE 7-10; Vuk=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=58ft; L=39ft; eave=5ft; Cat. <br />114-5-10, InteriorG) 14-5 10 to 29 8-0 (dExterior(2))29 8 0 t 35 1r10,2nteno (1) 35 70 D t t39 8-0 C fob members f t& <br />zone0C and <br />♦���`,�v1`1US <br />'• �i� <br />MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />3) Provide <br />♦♦� ,•'� (, E N S <br />�. lC•'•• <br />adequate drainage to prevent water ponding. <br />♦ <br />4) All plates are MT20 plates unless otherwise indicated. <br />N O 34869 10 <br />•� <br />5) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads. <br />' <br />* <br />6) This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />7) Provide mechanical connection others) of truss to bearing 100 lb <br />'0 : cc <br />(by plate capable of withstanding uplift at joint(s) except 0=11t) <br />2=716, 9=716. <br />8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum <br />40 <br />'��,♦♦ <br />sheetrock be applied directly to the bottom chord. <br />�• R , P <br />E%% <br />/0NAl <br />Julius Lee PE No.34869 <br />MiTek USA, Inc. FL Cert 6634 <br />6904 Parke East Blvd. Tampa FL 33610 <br />Date: <br />June 12,2020 <br />� aWARNIN(3 - Verify design parameters and READ NOTES ON THIS AND INCLUDED MIrEK REFERENCE PAGE Mk-7477 rev. 10/032015 BEFORE USE. <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not , <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing WOW <br />always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrM1 Quality Criteria, DSS40 and SCSI Bulkling Component 6904 Parke East Blvd. <br />Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 <br />