Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />Dupont <br />T20455633 <br />772591-X <br />B1 <br />Hip Girder <br />1 <br />1 <br />Job Reference (optional) <br />American Builder Supply, Sanford, FL 8,330 s May 6 2020 MTek Industries, Inc. Fri Jun 1213:48:52 2020 Page 1 <br />ID: R WGiORDIF509gYXBdOupOozldd5-uJwsGTaBFt9NrPDPV_S25uMCnSuk4cDyTNdQ5Kz7?tf <br />7-0-0 10 0 0 13-0-0 20-04) <br />7-0-0 3-0 0 3-0 0 7-0-0 1-0 0 <br />FJFRWr— <br />Special NAILED <br />4x8 = Special <br />NAILED 2x4 I 4x8 = <br />2 17 3 18 4 <br />3x8 = 2x4 11 4x4 = NAILED 3x8 = 2x4 11 3x8 = <br />Special <br />NAILED <br />Special <br />Scale = 1:35.6 <br />7-0-0 10-0-0 <br />13 0-0 <br />20-0-0 <br />7-0 0 3-0 0 <br />3-0-0 <br />7-0-0 <br />Plate Offsets (X,Y) - <br />[1:0-8-0,0-0-2], [2:0-5-4,0-2-0], [4:0-5-4,0-2-0], [5:0-8-4,0-0-14] <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. in <br />(loc) I/defl Lid <br />PLATES GRIP <br />TOLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.59 <br />Vert(LL) -0.12 <br />8 >999 360 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.99 <br />Vert(CT) -0.24 <br />7-16 >985 240 <br />BCLL 0.0 ' <br />Rep Stress Incr NO <br />WB 0.23 <br />Horz(CT) 0.08 <br />5 n/a n/a <br />BCDL 10.0 <br />Code FBC2017/TP12014 <br />Matrix -MS <br />Wind(LL) 0.16 <br />10-13 >999 240 <br />Weight: 86 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP M 30 -Except- <br />TOP CHORD <br />Structural wood sheathing directly applied or 3-2-4 oc purlins. <br />2-4: 2x4 SP No.2 <br />BOT CHORD <br />Rigid ceiling directly applied or 5-1-13 oc bracing. <br />BOT CHORD 20 SP M 30 *Except* <br />5-9: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 1=0-8-0, 5=0-8-0 <br />Max Horz 1=-121(LC 6) <br />Max Uplift 1=-663(LC 8), 5=741(LC 8) <br />Max Grav 1=1462(LC 1), 5=1518(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 1-2=-3212/1457, 2-3=-3107/1486, 3-4=3107/1486, 4-5=3206/1449 <br />BOT CHORD 1-10=-121312904, 8-10=-1217/2932, 7-8=1208/2926, 5-7=-1205/2898 <br />WEBS 2-10=69/614. 2-8=278/364, 3-8=324/301, 4-8=-276/367, 4-7=59/610 <br />NOTES- <br />1) Unbalanced roof live loads have been considered for this design <br />2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=58ft; L=39ft; eave=5ft; Cat.� <br />Exp Encl., GCpi=0.18; MWFRS <br />, <br />11; C; (directional); Lumber DOL=1.60 plate grip DOL=1.60 <br />�`` �`�V g �� <br />� <br />3) Provide adequate drainage to prevent water ponding. <br />4) All MT20 indicated. <br />�� • •.. 0 <br />C E �•. <br />plates are plates unless otherwise <br />,�� ,•'� INS* <br />V F ••. <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />�� <br />6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />34869 <br />•: <br />will fit between the bottom chord and any other members. <br />= * * = <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 663 lb uplift at joint 1 and 741 lb uplift at <br />•: <br />joint 5. <br />8) "NAILED" indicates 3-10d (0.148"x3") or 3-12d (0.148"x3.25") toe -nails per NDS guidlines. <br />; 'fl • .: <br />9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 297 lb down and 326 lb up at <br />p <br />7-0-0, and 297 lb down and 326 lb up at 13-0-0 on top chord, and 378 lb down and 113 lb up at 7-0-0, and 378 lb down and 113 lb <br />12-11-4 bottom The design/selection <br />.0O <br />40 <br />up at on chord. of such connection device(s) is the responsibility of others. <br />•� O <br />10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). <br />�j` (j <br />ON <br />LOAD CASE(S) Standard <br />, <br />,//111111111111110 <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 <br />Uniform Loads (plf) <br />Julius Lee PE No.34869 <br />Vert: 1-2=54, 2-4=54, 4-6=54. 11-14=-20 <br />MTTek USA, Inc. FL Cart 6634 <br />Concentrated Loads (lb) <br />6904 Parke East Blvd. Tampa FL 33610 <br />Vert: 2=-166(F) 4=166(F) 10=378(F) 7=-378(F) 17=116(F) 18=-116(F) 19=-63(F) 20=-63(F) <br />Date: <br />June 12,2020 <br />ICI AWARNING. Verify design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE I0110-7473 rev. 1010312015 BEFORE USE. <br />. <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />MTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPlt quality CrKens, DSO-89 and SCSI Building Component <br />6904 Parke East Blvd. <br />SarefylrNormstibn available from Truss Plate Institute, 218 N. Lee Strest, Suite 312, Alexandria, VA 22314. <br />Tampa, FL 36610 <br />