Laserfiche WebLink
Job <br />cuss <br />Truss Type <br />Qty <br />Ply <br />Dupont <br />T20455621 <br />772591-X <br />[A3 <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />American Builder Supply, Sanford, FL 8.330 s May 6 2020 MiTek Industries, Inc. Fri Jun 12 13:48:43 2020 Page 1 <br />ID:RWGiORDiF509gYXBdOupOozldd5-fbtTNOTXN6OfG01 gTboxD_UgaggFT05dOTySHLz7?to <br />0 q 71i 0 15-0-0 17 0 0, 19�{ 0 21 8 0 , 23 8 0 31-2-0 38.8-0 3" Q <br />7-fi0 7.6-0 2.0-0 2h-0 2-4.0 2-0-0 7&-0 7.6.0 -0- <br />5.00 12 <br />5x8 = <br />3x8 = <br />3x4 <br />5x6 = <br />5x8 = 3x4 <br />7x8 = 4x6 = 3x4 = <br />10-0-0 19.4-0 28-8-0 38-8-0 <br />10-0-0 9-4.0 9-4.0 10-0-0 <br />Plate Offsets (X,Y)—[3:0-3-0,0-3-41,[5:0-3-0,0-2-41,[6:0-3-0,0-2-4],[8:0-3-0,0-3-4],(9:0•4-2,0-1-8],[13:0-4-0,0-2-81,[14:0-4-0,0-3-01 <br />3x8 = <br />Scale = 1:71.2 <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2017/TPI2014 <br />CSI. <br />TC 0.62 <br />BC 0.95 <br />WB 0.80 <br />Matrix -AS <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in (loc) I/clef! L/d <br />-0.32 13-14 >999 360 <br />-0.58 13-14 >801 240 <br />0.13 9 n/a n/a <br />0.28 13 >999 240 <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 201 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />BOT CHORD 2x4 SP M 30 `Except` <br />BOT CHORD <br />Rigid ceiling directly applied. <br />12-14: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-8-0, 9=0-8-0 <br />Max Horz 2=-279(LC 10) <br />Max Uplift 2=716(LC 12), 9=716(LC 12) <br />Max Grav 2=1506(LC 17). 9=1506(LC 18) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3123/1806, 3-4=-2883/1704, 4-5=1933/1326, 5-6=-1952/1342, 6-7=1933/1326, <br />7-8=2883/1704, 8-9=-3123/1806 <br />BOT CHORD 2-14=-1545/3041, 13-14=1079/2237, 11-13=-1087/2100, 9-11=1553/2831 <br />WEBS 3-14=-478/443, 4-14=-300/805, 7-11=299/804, 8-11=-478/443, 5-13=398/662, <br />6-13=398/663,4-13=-726/589, 7-13=-727/589 <br />NOTES- <br />1) Unbalanced roof live loads have been considered for this design. <br />Wind: <br />1GCpi=O <br />ASCE <br />2) 11; Exp C; Encl., 180 MWFRS C-C4Extenor(2D 1-0-0 2- 0-6 2- 0-6 Exterior(2) <br />&JU S F�CJI.- <br />(directional) and to n enor(1) to817-0.0, 17-0-0 <br />♦�� <br />to 27-1-10, Interior(1) 27-1-10 to 39-8-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate <br />3) Provide adequate drainage to prevent water ponding. <br />+ 34869 0 <br />• •� <br />4) All plates are MT20 plates unless otherwise indicated. <br />* .; <br />= * : <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />fit between the bottom <br />f <br />'fl <br />will chord and any other members, with BCDL = I O.Opsf. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) <br />2=716, 9=716. <br />p % 4 <br />••, �(/ <br />8) This truss design requires that a minimum of 7/16' structural wood sheathing be applied directly to the top chord and 1/2" gypsum <br />i <br />�i�'n,1� Q Q:� ��♦♦♦ <br />•• 0 R <br />sheetrock be applied directly to the bottom chord. <br />�j` ; �♦ <br />11111t% <br />Julius Lee PE No.34869 <br />MiTek USA Inc. FL Cart 6634 <br />6904 Parke East Blvd. Tampa FL 33610 <br />Date: <br />June 12,2020 <br />AWARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE ANI.7473 rev. 10/032015 BEFORE USE. <br />Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSU R1 Quality Criteria, D913-89 and SCSI Building Component 6904 Parke East Blvd. <br />Safetylntormadon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 36610 <br />