Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />DupontT20455623 <br />7tyPIy <br />772591-X <br />A5 <br />Hip <br />11 <br />Job Reference (optional) <br />American Builder Supply, Sanford, FL 8.330 s May 6 2020 MTek Industries, Inc. Fri Jun 12 13:48:45 2020 Page 1 <br />ID: RWGiORDIF509gYXBdOupOozldd5-bz?Do4UovjGN WKB3bOgP IPa?udVYxPswsnRYLEz7'?tm <br />-,1-0-q 7-6-0 13-0-0 19-4-0 25-8-0 , 31-2-0 , 38-11-0 39 8-0 <br />0-0 7 6 0 5&-0 6-0-0 6-4-0 5 6 0 7� 0 0 0 <br />5x6 = 2x4 II 5x8 = <br />4 21 22 5 23 24 6 <br />w — a 12 „ — 1. ,u <br />5x8 = 3x8 = 4x6 = 3x4 = <br />US = <br />3x8 = <br />Scale = 1 :69.9 <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2017/TPI2014 <br />CS1. <br />TC 0.70 <br />BC 0,96 <br />WB 0.34 <br />Matrix -AS <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in (loc) I/deft Ud <br />-0.29 12-13 >999 360 <br />-0.55 12-13 >836 240 <br />0.13 8 n/a n/a <br />0.31 12 >999 240 <br />PLATES GRIP <br />MT20 244/190 <br />Weight: 183 lb FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />BOT CHORD 2x4 SP M 30 `Except` <br />BOT CHORD <br />Rigid ceiling directly applied. <br />11-13: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-8-0, 8=0-8-0 <br />Max Horz 2=217(LC 10) <br />Max Uplift 2=-716(LC 12), 8=716(LC 12) <br />Max Grant 2=1485(LC 1), 8=1485(LC 1) <br />FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=3065/1895, 3-4=2826/1780, 4-5=2586/1716, 5-6=2586/1716, 6-7=2827/1780, <br />7-8=-3066/1895 <br />BOT CHORD 2-13=1626/2913, 12-13=-1206/2314, 10-12=1213/2267, 8-10=1633/2790 <br />WEBS 3-13=-425/449, 4-13=-273/678, 4-12=-252/567, 5-12=-384/390, 6-12=-251/566, <br />7-10=-425/449, 6-10=-273/678 <br />NOTES- <br />1) Unbalanced roof live loads have been considered for this design. <br />`ttJ11 � 1111111 <br />2) Wind: ASCE 7-10; Vint=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=58ft; L=39ft; eave=5ft; Cat. <br />II; Exp C; Encl., GCpi=0.18; MWFRS C-C Exterior(2) to 2-10-6, Interior(1) 2-10.6 to 13-0-0, Exterior(2) 13-0-0 <br />% J`raus <br />�j <br />(directional) and -1-0-0 <br />% <br />E #i� <br />to 18-5-10, Interior(1) 18-5-10 to 25-8-0, Exterior(2) 25-8-0 to 31-3-3, Interior(1) 31-3-3 to 39-8-0 zone;C-C for members and forces & <br />♦♦♦ ••'� G N S+'• <br />F•�•. 0 <br />MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />♦ V <br />3) Provide adequate drainage to prevent water ponding. <br />4) All plates are MT20 plates unless otherwise indicated. <br />N O 34869 <br />•� <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />* : <br />6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=1b) <br />0 •• �(/ <br />•�(/ <br />2=716,8=716. <br />�i <br />••• <br />8) This truss design requires that a minimum of 7/16" structural wood sheathing be applied directly to the top chord and 1/2" gypsum <br />` Q;•� ♦♦ <br />sheetrock be applied directly to the bottom chord. <br />0 • • �♦ <br />. <br />1111111��``` <br />Julius Lee PE No.34869 <br />MTek USA, Inc. FL Cert 6634 <br />6904 Parke Fast Blvd. Tampa FL 33610 <br />Date: <br />June 12,2020 <br />AWARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE. <br />- <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />MiTek' <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS&TP/1 Qua9ty C~a, DS849 and BCSI Building Component <br />6904 Parke East Blvd. <br />BMW Information available from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. <br />Tampa, FL 36610 <br />