Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />Dupont <br />T20455625 <br />772591-X <br />A7 <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />American Builder Supply, Sanford, FL 8.330 s May 6 2020 MiTek Industries, Inc. Fri Jun 12 13:48:48 2020 Page 1 <br />ID:R WGiORDIF509gYXBdOupOozidd5-OYgMR6XgCeeyNnveG8N6w2CVTrbM81UMYffDyZz7?tj <br />1 0 (} 5 8 11 9 M 16-2-15 22-6-1 + 29 8 0 32-11-5 3_ 36 8 Q <br />5 8 11 3-3-5 7-2-15 6-3.2 7-1-15 3-3 5 5-8.11 0 0 <br />Scale = 1:69.9 <br />3x6 = <br />5x6 = <br />5.o0 12 3x4 = <br />4 23 24 25 5 <br />5x6 = <br />26 27 <br />5x6 = <br />287 <br />14 13 12 11 <br />5x10 = <br />3x4 = 3x8 MT20HS = <br />3x8 = <br />3x6 = <br />4 <br />D <br />I¢ <br />LOADING (psf) <br />TCLL 20.0 <br />TCDL 7.0 <br />BCLL 0.0 <br />BCDL 10.0 <br />SPACING- 2-0-0 <br />Plate Grip DOL 1.25 <br />Lumber DOL 1.25 <br />Rep Stress Incr YES <br />Code FBC2017/TP12014 <br />CS1. <br />TC 0.68 <br />BC 0.70 <br />WB 0.41 <br />Matrix -AS <br />DEFL. in (loc) Vdefl L/d <br />Vert(LL) -0.33 13 >999 360 <br />Vert(CT) -0.69 13-14 >671 240 <br />Horz(CT) 0.16 9 n/a n/a <br />Wind(LL) 0.44 13 >999 240 <br />PLATES <br />MT20 <br />MT20HS <br />Weight: 180 lb <br />GRIP <br />244/190 <br />187/143 <br />FT = 20% <br />LUMBER- <br />BRACING - <br />TOP CHORD 2x4 SP No.2 <br />TOP CHORD <br />Structural wood sheathing directly applied. <br />BOT CHORD 2x4 SP M 30 <br />BOT CHORD <br />Rigid ceiling directly applied. <br />WEBS 2x4 SP No.3 <br />WEBS <br />1 Row at midpt 5-14, 6-11 <br />REACTIONS. (size) 2=0-8-0, 9=0-8-0 <br />Max Horz 2=155(LC 10) <br />Max Uplift 2=-716(LC 12), 9=716(LC 12) <br />Max Grav 2=1485(LC 1), 9=1485(LC 1) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3156/1984, 3-4=-2926/1806, 4-5=2670/1720, 5-6=-3662/2233, 6-7=2691/1729, <br />7-8=2914/1800, 8-9=-3153/1986 <br />BOT CHORD 2-14=1720/2881, 13-14=2010/3580, 11-13=-2002/3574, 9-11=-1730/2878 <br />WEBS 3-14=304/349, 4-14=-386/829, 5-14=1121/709, 5-13-0/269, 6-13=0/271, <br />6-11=1095/698, 7-11=-386/829, 8-11=312/353 <br />NOTES- (9) <br />1) Unbalanced roof live loads have been considered for this design <br />2) Wind: ASCE 7-10; VuR=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=6.Opsf; h=15ft; B=58ft; L=39R; eave=5ft; Cat. <br />`, 11111111rrrr� <br />14-5-10, I teriiorG) 14-5-10 to 29-8-0,(Exterio to35-1-10, Interior(1) 35-1 1to0 t39-8-0 for orcest& <br />,,��`,us <br />(2))29-" zo e;�C-C embers and <br />MWFRS for Lumber DOL=1.60 <br />E N •• �i� <br />reactions shown; plate grip DOL=1.60 <br />,�� e•'�G S F•••• �.0 <br />3) Provide adequate drainage to prevent water ponding. <br />�� • <br />4) All plates are MT20 plates unless otherwise indicated. <br />: 34869 <br />•� <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />' <br />* <br />6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />7) Provide mechanical connection truss to bearing 100 lb <br />r <br />(by others) of plate capable of withstanding uplift at joints) except 0=1b) <br />2=716, 9=716. <br />fi �• �(/ <br />8) This truss design requires that a minimum of 7116" structural wood sheathing be applied directly to the top chord and 1/2" gypsum <br />sheetrock be applied directly to the bottom chord. <br />•• t(/ <br />40 P •• <br />9) NOT SYMETRICAL <br />,f� ����� <br />�j` •• • - R , <br />�r1,��. <br />.,"111 <br />rrr►nn1111` <br />Julius Lee PE No.34869 <br />MTek USA, Inc. FL Cen 6634 <br />6904 Parke East Blvd. Tampa FL 33610 <br />Date: <br />June 12,2020 <br />AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED WTEK REFERENCE PAGE 11111-7473 rev. 10103/2015 BEFORE USE. <br />Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />WOW <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPoI Quality CdteM, DSB419 and SCSI Building Component <br />69D4 Parke East Blvd. <br />Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. <br />Tama, FL 36610 <br />