Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T32315708 <br />TTH133-140 <br />T07 <br />Hip <br />1 <br />1 <br />Job Reference (optional) <br />Builders FirstSource (Tampa, FL), Tampa, FL - 33564, 8,730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:14 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-CzYPnBaFgSB6laOQtkgLa_WOmkHEgM1 DIOQJ?cyB?y? <br />13-0 0 19-1-8 23-10-8 30A-0 35-11-15 43-0-0 4q-0-0 <br />7-0-1 5-11-15 6-1-8 4-9-0 6-1-8 5-11-15 7-0-1 -0. <br />5x6 = <br />5.00 12 <br />5x8 = <br />Scale = 1:75.2 <br />3x8 = io n cc 11 16 Zit 15 'q L4 Zo io 3x8 = <br />3x4 = 5x6 WB = 3x8 = <br />3x4 = 5x6 WB = <br />3x4 = <br />I� <br />9-10-15 19-1-8 23-10-8 33-1-1 <br />43-0-0 <br />9-10-15 9-2-9 4-9-0 9-2-9 <br />9-10-15 <br />Plate Offsets (X,Y)-- [2:0-4-2,0-1-8], [6:0-3-0,0-2-4], [7:0-5-12,0-2-8], [11:0-4-2 0-1-8] <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. in (loc) I/defl L/d <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.73 <br />Vert(LL) -0.40 13-15 >999 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.96 <br />Vert(CT) -0.70 13-15 >728 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.41 <br />Horz(CT) 0.17 11 n/a n/a <br />BCDL 10.0 <br />Code FBC2020/TPI2014 <br />Matrix-SH <br />Weight: 228 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-3-0 oc purlins. <br />1-4,9-12: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. <br />BOT CHORD 2x4 SP 285OF 2.0E or 2x4 SP M 31 'Except* WEBS 1 Row at midpt 5-16, <br />7-16. 8-15 <br />14-17: 2x4 SP No.2 <br />WEBS 2x4 SP No.3 <br />OTHERS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 11=0-3-8 <br />Max Horz 2=267(LC 11) <br />Max Uplift 2=-943(LC 12), 11=-943(LC 12) <br />Max Grav 2=1871(LC 17). 11=1873(LC 18) <br />FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. <br />TOP CHORD 2-3=-3899/2048, 3-5=-3656/1936, 5-6=-2628/1546, 6-7=-2388/1500, 7-8=-2631/1546, <br />8-10=-3661/1936, 10-11=-3905/2048 <br />BOT CHORD 2-18=-1764/3735, 16-18=-1422/3112, 15-16=-1019/2395, 13-15=-1434/2951, <br />11-13=-1776/3539 <br />WEBS 3-18=-351/346, 5-18=-214/750, 5-16=-877/557, 6-16=-330/762, 7-15=-326/836, <br />8-15=-879/558, 8-13=-214/751, 10-13=-351/346 <br />NOTES- (8) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 19-1-8, Exterior(2E) <br />This item has been <br />19-1-8 to 23-10-8, Exterior(2R) 23-10-8 to 30-0-0, Interior(1) 30-0-0 to 44-0-0 zone; cantilever left and right exposed ; end vertical left <br />and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />electronically signed and <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />sealed by Velez, Joaquin, PE <br />to the use of this truss component. <br />using a Digital Signature. <br />4) Provide adequate drainage to prevent water ponding. <br />Printed COpI@S Of this <br />5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />document are not considered <br />will fit between the bottom chord and any other members, with BCDL=10.0psf. <br />signed and sealed and the <br />7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 943 lb uplift at joint 2 and 943 lb uplift at <br />signature must be verified <br />joint 11. <br />on any electronic copies. <br />8) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />Joaquin Velez PE Ne.68132 <br />.NBT.k lac. DRA 3JIT'ek USA FL C'-i 6634 <br />16023 Swtadev Ridge Rd. <br />Chesterfield, MO 0017 <br />Dale: <br />December 11,2023 <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. I �� �x <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and ppropertrtyy damage. For general guidance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage. delivery, erection and bracing of trusses and truss systems, see ANSlrrrll Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com <br />