Laserfiche WebLink
Job <br />Truss <br />Truss Type <br />Qty <br />Ply <br />T32315713 <br />TTH133-140 <br />T11 <br />Common <br />8 <br />1 <br />Job Reference (optional) <br />Builders FirslSource (Tampa, FL), Tampa, FL - 33564, 8.730 s Nov 13 2023 MiTek Industries, Inc. Fri Dec 8 13:48:22 2023 Page 1 <br />ID:tPuYCeVfQTfYt3OC?ZvfnpzlGUH-zW1 RSwgGyv9JodyLPpDvgrjsy0nigyPbGMkGByB?xt <br />-r1-0-Q 7-7-3 14-0-10 21- 0 28-5-6 35-4-13 43-0-0 45-0-0 <br />-10 7-7-3 6-11-6 6-11-6 6-11-6 6-11-6 7-7-3 <br />Scale = 1:73.7 <br />5x6 = <br />5.00 12 <br />11i <br />3x4 = 4x6 = 3x4 = 3x4 = <br />3x4 = 4x6 = <br />9-0-0 17-3-15 25-8-1 <br />33-11-10 43-0-0 <br />9-021 8-3-10 8-4-1 <br />+ 8-3-10 9-0-6 <br />Plate Offsets (X,Y)— [2:0-4-2,0.1-8], [4:0-3-0,Edge], [8:0-3-0,Edge], [10:0-4-2,0-1-8] <br />LOADING (psf) <br />SPACING- 2-0-0 <br />CSI. <br />DEFL. <br />in (loc) I/deft L/d <br />PLATES GRIP <br />TCLL 20.0 <br />Plate Grip DOL 1.25 <br />TC 0.91 <br />Vert(L-) <br />-0.40 14-15 >999 240 <br />MT20 244/190 <br />TCDL 7.0 <br />Lumber DOL 1.25 <br />BC 0.92 <br />Vert(CT) <br />-0.68 14-15 >755 180 <br />BCLL 0.0 <br />Rep Stress Incr YES <br />WB 0.99 <br />Horz(CT) <br />0.18 10 nla n/a <br />BCDL 10.0 <br />Code FBC20201TPI2014 <br />Matrix-SH <br />Weight: 220 lb FT = 20% <br />LUMBER- BRACING - <br />TOP CHORD 2x4 SP No.2 *Except* TOP CHORD <br />Structural wood sheathing directly applied. <br />1-4,8-11: 2x4 SP No.1 BOT CHORD <br />Rigid ceiling directly applied or 2-2-0 oc bracing. <br />BOT CHORD 2x4 SP No.1 <br />WEBS 2x4 SP No.3 <br />REACTIONS. (size) 2=0-3-8, 10=0-3-8 <br />Max Horz 2=-310(LC 10) <br />Max Uplift 2=-939(LC 12), 10=-1020(LC 12) <br />Max Grav 2=1885(LC 17), 10=1934(LC 18) <br />FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 2-3=-3930/1998, 3-5=-3800/2006, 5-6=2887/1656, 6-7=-2886/1647, 7-9=-3779/1968, <br />9-10=-3921/1959 <br />BOT CHORD 2-17=-1668/3790, 15-17=-1252/3027, 14-15=-827/2225, 12-14=-1281/2868, <br />10-12=-1668/3535 <br />WEBS 6-14=-516/1150, 7-14=-758/569, 7-12=-359/890, 9-12=-354/345, 6-15=-519/1153, <br />5-15=-763/575, 5-17=-392/908, 3-17=-362/365 <br />NOTES- (7) <br />1) Unbalanced roof live loads have been considered for this design. <br />2) Wind: ASCE 7-16; VuR=150mph (3-second gust) Vasd=116mph; TCDL=4.2psf; BCDL=3.Opsf; h=25ft; B=45ft; L=43ft; eave=5ft; Cat. <br />II; Exp C; Encl., 13Cpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-0-0 to 3-3-10, Interior(1) 3-3-10 to 21-6-0, Exterior(2R) <br />21-6-0 to 25-9-10, Interior(1) 25-9-10 to 45-0-0 zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for <br />members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 <br />This item has been <br />3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific <br />to the use of this truss component. <br />electronically signed and <br />4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />sealed by Velez, Joaquin, PE <br />5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />using a Digital Signature. <br />will fit between the bottom chord and any other members, with BCDL = 10.Opsf. <br />Printed COpleS Of this <br />6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Ot=lb) <br />document <br />2=939, 10=1020. <br />are not considered <br />7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any <br />signed and sealed and the <br />particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." <br />signature must be verified <br />on any electronic copies. <br />Jmagmla Velez PF N..69122 <br />MITek tar. DBA MITek CSA F'L Carr 66d4 <br />16023 tiwiylov "e Rd. <br />Ch.1-11e1d. MO 63017 <br />Date: <br />December 11.2023 <br />a WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 1/2/2023 BEFORE USE. ■ <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not MiTeV <br />a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general g Adance regarding the 16023 Swingley Ridge Rd. <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, we ANSI7rrI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) Chesterfield, MO 63017 <br />and BCSI Building Component Safety Information available from the Structural Building Component Association (www.sbcscomponents.com) 314.434.1200 / MTek-US.com <br />