My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7050 Gall Blvd (136)
Zephyrhills
>
Building Department
>
Building Plans
>
7050 Gall Blvd (136)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:26:50 AM
Creation date
2/28/2025 8:03:43 AM
Metadata
Fields
Template:
Building Plans
Street #
7050
Location
Gall Blvd
Contractor
Brasfield and Gorrie LLC
Building Plans - Permit #
17470
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Test Laboratory: Hurricane Test Laboratory, Inc. (HTL) & Architectural Testing, Inc. (ATI). <br />Note that HTL is now known as Intertek Architectural Testing, Inc.) <br />Test report numbers: <br />HTL reports 0049-1106-00, 0049-0406-01 & 0049-0202-05; ATI reports B8873.01-550- <br />18. Note: All HVHZ test reports have been signed & sealed by a Florida PE. <br />General report notes & system limitations: <br />l . All size & installation conditions shown in this report, the referenced drawing No. 1790 <br />and Addendum "A" are based off the referenced test reports and/or engineering analysis <br />in accordance with the Florida Building Code. <br />2. Curtain wall shall be constructed in accordance with the descriptions in this report, and <br />the manufacturer's state approved quality assurance entity specifications. <br />3. This product is approved for use in & outside of the High Velocity Hurricane Zones <br />(HVHZ). <br />4. Job required design wind pressure shall be calculated in accordance with the Florida <br />Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other <br />Structures (0.85 directionality factor may apply per the current ASCE 7 standard). <br />5. This curtain wall is small missile impact rated and may not be installed at elevations <br />below 30 ft. above grade or at any code designated large missile impact location without <br />an approved shutter. <br />6. Dry glazing gaskets are in accordance with ASTM C864 <br />7. When applicable, all safety glass requirements must be met per FBC chapter 24. <br />(ATI) Architectural Testing, Inc. <br />APR 0 8 2016 <br />Warre . Schaefer, P.E. <br />Flo ' P.E. #44135 <br />
The URL can be used to link to this page
Your browser does not support the video tag.