C408.2.2. <br />Air system balancing accomplished in <br />'HComplies <br />1 <br />a manner to first minimize throttling <br />❑Does Not <br />[ME53]3 <br />;losses, then for fans with fan system <br />power greater than 1 hp, fan speeds <br />❑Not Observable <br />shall be adjusted to meet design flow❑Not <br />Applicable <br />conditions. Balancing procedures shall <br />be in accordance with NEBB <br />Procedural Standards, the AABC, <br />National Standards, or equivalent <br />3 <br />procedures. <br />C403.2.6. <br />'Demand control ventilation provided <br />❑Complies <br />1 <br />for spaces >500 ft2 and >25 <br />❑Does Not <br />[ME59]1 <br />people/1000 ft2 occupant density and <br />❑Not Observable <br />served by systems with air side <br />Applicable <br />!economizer, auto modulating outside❑Not <br />air damper control, or design airflow <br />>3,000 cfm. <br />C403.2.6, <br />:Enclosed parking garage ventilation <br />LJComplies <br />2 <br />has automatic contaminant detection <br />❑Does Not <br />[ME115]3 <br />and capacity to stage or modulate <br />❑Not Observable' <br />:fans to 50% or less of design capacity. <br />❑Not Applicable <br />C403.2.7 <br />Exhaust air energy recovery on <br />❑Complies <br />[ME57]1 <br />systems meeting Table C403.2.7(1) <br />❑Does Not <br />and C403.2.7(2). <br />❑Not Observable <br />[]Not Applicable <br />C403.2.8 <br />Kitchen exhaust systems comply with❑Complies <br />[ME116]3 <br />replacement air and conditioned <br />❑Does Not <br />supply air limitations, and satisfy hood <br />❑Not Observable' <br />rating requirements and maximum <br />❑Not Applicable <br />exhaust rate criteria. <br />C403.4.4. <br />Multiple zone VAV systems with DDC <br />LJComplies See the Mechanical Systems list for values. <br />6 <br />of individual zone boxes have static <br />❑Does Not <br />[ME110]3 <br />`pressure setpoint reset controls. <br />❑Not Observable <br />❑Not Applicable <br />C403.4.4. <br />Multiple zone VAV systems with DDC <br />❑Complies See the Mechanical Systems list for values. <br />6 <br />of individual zone boxes have static <br />❑Does Not <br />[ME'110]3 <br />pressure setpoint reset controls. <br />❑Not Observable <br />❑Not Applicable '. <br />C403.4.4. Multiple zone VAV systems with DDC LJComplies I See the Mechanical Systems list for values. <br />6 eof individual zone boxes have static I❑Does Not <br />[ME11013 ,pressure setpoint reset controls. <br />i❑Not Observable <br />❑Not Applicable <br />C408.2.2. 'Air outlets and zone terminal devices <br />LJComplies <br />1 <br />have means for air balancing. <br />❑Does Not <br />[ME53]3 <br />❑Not Observable ; <br />❑Not Applicable <br />C403.5, <br />Refrigerated display cases, walk-in <br />❑Complies <br />C403.5.1, <br />,'coolers or walk-in freezers served by <br />❑Does Not <br />C403.5.2 <br />remote compressors and remote <br />'condensers <br />❑Not Observable; <br />[ME12313 <br />not located in a <br />❑Not Applicable <br />condensing unit, have fan -powered <br />condensers that comply with Sections <br />C403.5.1 and refrigeration compressor. <br />,systems that comply with C403.5.2.. <br />1 High Impact (Tier 1) T 2 Medium Impact (Tier 2) Low Impact (Tier 3)� <br />Project Title: P13-LC LRG Report date: 07/30/20 <br />Data filename: F:\Prototypes\Chick-fil-A\2020-CFA Projects\CFA New Store Projects\20090.CC.S - Zephyrhills, FI Page 12 of 20 <br />4040\zComCheck\CFA-4040-P13 LC_LRG-Florida Energy Code.cck <br />