Metadata
Fields
Template:
Building Plans
Street #
360
Location
S Rosemary Ave Ste 400
Contractor
Superior Fire Alarm
Building Plans - Permit #
5454-5455
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OF� i� POTTER AFC-100 <br />The Symbol of Protection Fire Alarm Control Panel <br />Features <br />100 addresses available on this analog addressable system <br />• Additional system capacity achieved via multi -point SLC modules <br />• 99 software zones <br />• NFPA 72 Compliant Smoke Settsitiyit\ Test Built -In <br />• System Operates as Class A or Class B for SLC, P-Link and NACs <br />• 5 Amp Power Supph. Expandable to 3 10 amps <br />• 2 NACS, Regulate, Rated at 3 Amps each. expandable to 188 <br />• 2 Input/Output (r/O) Circuits t'tr system flexibility rated at I Amp <br />each <br />• Strobe Synchronization and System Wide Sync for Gentex1_ <br />AMSEC03, Cooper WheelockR and S}stem Sensor!( strobes <br />• Dedicated Alarm, Supervisory and Trouble Relays <br />• 4,000 Event History Buffer <br />• Optional two line DACT with UD-2000 that can report General, <br />Zone or Point Information <br />• Built in IP Communicator <br />• Ethernet Port for Programming and Network Connectivity <br />CbparTFR <br />• E-Mail System Status, Reports and Event Information O NYC Fire Dept.y; <br />• Product includes 5 vear warranty FM Certificate ohApproval 4 <br />6256 `� LISTED <br />APPROVED 7165-0328:0509 S735 <br />Description <br />The AFC-100 is an analog/addressable fire alarm system with a total <br />system capacity of 100 addresses. Additional capacity on the system is <br />achieved using multi -point SLC modules. The control panel utilizes the <br />exclusive Potter protocol that includes a complete line of sensors and <br />modules. Each SLC may be comprised of any combination of smoke <br />sensor, heat detectors or modules and allows for a total of 50 ohms of <br />impedance and ma} use any wire compliant with the National Electrical <br />Code (NEC). <br />The AFC-100 has a 5 Amp power supply with two Notification <br />Appliance Circuits (NACs) and two htpuUoutput (1/0) circuits. The <br />NACs are rated at 3 Amps each and the I/Os are rated at 1 Amp each. <br />Each output is regulated and power limited. In addition. each output is <br />uniquely programmable and may be configured Ibr steady signal. strobe <br />synchronization, constant power, door holder power. or releasing. The <br />strobe synchronization includes Gentex, AMSLCCI, System Sensor and <br />Cooper/Wheelock and with the exclusive Quadrasvnc each output may <br />have a unique brand and all strobes will flash together. <br />The NACs may be expanded using the PSN-1000 series intelligent power <br />supplies. Each PSN-1000 adds another 10 Amps of power, 2 additional <br />input circuits and the AFC-100 will support up to 31 power supplies. The <br />system will synchronize the strobes system wide. In addition. the PSN- <br />1000E has space to allow the installation of up to six loop expansion cards. <br />The cards mount on a stacker bracket that allow s access to all SLC circuit <br />connections. <br />Technical Specifications <br />Dimensions <br />16"W' x 1711 x 3 '/8"D <br />AC Mains <br />3.0 Amps '�ti 120 VAC 50/60 IIZ <br />2.0 Amps fir; 240 VAC 50/60 HZ <br />Enclosure <br />16 gauge cold rolled steel with removable <br />locked door with Lexan viewing window <br />Standby Carrcnt-130 mA <br />Alarm Current-200 mA <br />• 5 Amps power for NACs, 1/0, and P-Link <br />Battery <br />3 Amps per NAC, regulated <br />• 1 Amp per 1/0 circuit, regulated <br />• Battery Charger range 8-55 Ah <br />• Battery Charger voltage 27.3 VDC <br />• P-Link maximum current of I Amp <br />Temperature and <br />32' to 120' (0°C to 49°C) with a maximum <br />Humidity Range <br />humidity of 93% non -condensing. <br />Potter Electric Signal Company. LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8830134 - REV E • 9.19 PAGE I OF 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.