My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
360 S Rosemary Ave Ste 400 (2)
Zephyrhills
>
Building Department
>
Building Plans
>
360 S Rosemary Ave Ste 400 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/28/2025 11:25:50 AM
Creation date
2/27/2025 11:14:47 AM
Metadata
Fields
Template:
Building Plans
Street #
360
Location
S Rosemary Ave Ste 400
Contractor
Superior Fire Alarm
Building Plans - Permit #
5454-5455
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E)POTTER <br />The Symbol of Protection <br />Features <br />• One (1) Form C relay contact <br />• SLC Class A. Class X & Class B <br />• Mounts in a standard 4" or double gang box <br />• Wiring terminals accessible when mounted in box <br />• All wiring terminals accept 22 to 12 AA'G <br />• Product includes a 5 year warrant} <br />• UUKL Listed for Smoke Control <br />Description <br />The PAD100-RM uses one (1) SLC loop address to provide one (1) <br />Form C relay contact. The module mounts on either a 4" square or <br />double gang box. The PAD 100-RM includes one red LED to indicate <br />the module's status. In normal condition. the LED flashes when the <br />device is being polled by the control panel. <br />Application <br />The PAD100-RM is compatible with Potter's IPA and AFCIARC. <br />series addressable fire alarm control panels. The PAD100-RM is an <br />interface module providing one (I) Form C relay contact. <br />Setting the Address <br />Each addressable SLC device must be assignted an address. The <br />address is set using the DIP switch located on the PADI00-RM. The <br />PAD OO-RM uses a single device address to identity relay contacts. <br />Before connecting a device to the SLC loop, take the following <br />precautions to prevent potential damage to the panel or device: <br />1. Power to the device is removed. <br />2. Field wiring is correctly installed <br />3. Field wiring has no open or short circuits <br />PAD100-RM <br />Relay Module <br />N7 <br />9 <br />�aunor+ <br />APPROVED <br />J c <br />Technical Specifications <br />Operating Voltage <br />24.OV <br />Max SLC Standby <br />240µA <br />Current <br />Max SLC Alarm <br />240µA <br />Current <br />Relay Contacts <br />2A (cc:�30VDC, 0.5A (c 125VAC <br />Operating Temperature <br />Range <br />32 to 120°F (0 to 49°C) <br />Operating Humidity <br />Range <br />0 to 93`%, (non -condensing) <br />Max no. of Module Per <br />127 units <br />Loop <br />Dimensions <br />4.17" (106mm)L x 4.17" <br />(I06mm)W x 1.14" (29mm)D <br />Mounting Options <br />Standard 4" Square or <br />Double Gang Box <br />Shipping Weight <br />0.6 lbs <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8830084 -REV D • 1218 PAGE I OF 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.