(E)POTTER <br />The Symbol of Protection <br />Air Velocity Ratings <br />The PAD100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. <br />PAD100-PD <br />Photoelectric Smoke Sensor <br />The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on. the PAD 100-PD will operate even <br />though the LED may not illuminate. <br />Operation <br />The PAD100-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SEC) of a compatible fire alarm control panel. <br />The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is <br />in an active status. The polling LED can be turned off if desired for less conspicuous operation. <br />The PAD100-PD with the PAD I00-4DB or PAD100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The <br />sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. <br />Sensor Sensitivity <br />The PAD100-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time. the sensor <br />compensates for the dirt in the unit until it is out of range. At that time. the panel will indicate a dirty sensor. The sensor will then have to be cleaned <br />or replaced. <br />The PAD 100-PD can be programmed to pro%ide a maintenance alert prior to reaching the dirty sensor level xvhich will allow for intervention prior to <br />the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. <br />A0IT: As required by NFPA. do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors <br />have been installed in a construction cn\ ironment, they should be cleaned or replaced before the system is placed into service. <br />Spacing <br />The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, <br />placement and special applications. <br />Compatible Bases <br />All bases will mount on a single gang. double gang. octagon. 4" square or mud ring electrical box. <br />Device <br />Description <br />Stock No. <br />PAD100-4DB <br />4" Standard Base <br />3992731 <br />PAD100-6DB <br />6" Standard Base <br />3992732 <br />PAD100-I13 <br />6" base with an isolator module included. <br />3992730 <br />PAD100-RB <br />6' base with one Form-C' relay contact. 2A rd; 30VDC, 0.5A ci; 125VAC <br />3992728 <br />PAD100-SB <br />6" base with sounder module included. Sound pattern is provided from external source. <br />3992729 <br />PAD 100-SPKB <br />6" base with speaker included <br />3992762 <br />Ordering Information <br />Model <br />Description <br />I Stock No. <br />PAD 100-PD <br />Photoelectric Smoke Sensor <br />139927333 <br />Potter Electric Signal Company. LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />..... _ - _.... <br />8830108 - REV D • 12 1 S PAGE 2 OF 2 <br />