My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
38508 A Ave (3)
Zephyrhills
>
Building Department
>
Building Plans
>
38508 A Ave (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 4:59:41 PM
Creation date
2/25/2025 12:50:39 PM
Metadata
Fields
Template:
Building Plans
Street #
38508
Location
A Ave
Contractor
United Fire Protection
Building Plans - Permit #
15218
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPTIONAL MODULES AND PERIPHERALS <br />Supplemental Power Supply (SPS) (P/N 10-2474-P)* <br />The 10-2474 p includes the power supply circuit board and transformer (-1 for 120VAC primary; -2 for 240Vt1C primary). <br />This module adds up to 2.OA external standby power and 6.OA alarm power (4 i standby/12:'� alarm total). AC: power and <br />standby batteries are supervised. Supports charging up to 75.'�h of additional standby battery. Charging may be turned off in <br />configuration if batteries are not required on SPS. Control Board dimensions: 4-1/2" L x 5-1/2" H x 2" D. Weight: 0.66 <br />lbs. Transformer dimensions: 5" L x 3-3/4" H x 3-1/2" D. Weight: ,'• lbs. <br />Supplemental Loop Module (SLM), (P/N 10-2473)* <br />T'he SLM adds two more SL,C loops. Loop specifications and wiring for SLA1: are the same as the main controller. It <br />interfaces to the main Control Panel using four standoffs supplied with the SI,M. Dimensions: 2" I, x 6-1,/2" H x 1"D. <br />Weight: 0.12lbs. <br />Point ID Dact (Digital Alarm Communicator Transmitter) Module (P/N 10-2528)* <br />The DACT provides interface with Central Station monitoring systems. It is available with 5 contact zones of connection <br />OR the intelligent serial interface which provides point ID information. The Contact ID form is the preferred reporting <br />format. It provides a four digit account code followed by a three digit event code, a two -digit group number, and a three <br />digit contact number, all of which are used to pro,6de specific point identification. This DACT can also provide an SIA <br />or 4/2 Pulse reporting format. Note: 10-2476 is the same as 10-2528 wzth enclosure for external mounting. Dimensions: <br />6-1/2" I, x 4" 11 x 1" D. Weight 0.32 lbs. <br />Fike Relay Module (P/N 10-2204)* <br />The CRlt14 provides 4 additional independently programmed relays. Cheetah hi Control Panel supports up to 2 CRD44 <br />modules (if either options are not unused) on the main controller board. Each relay may be wired across normally open or <br />normally closed contacts. Dimensions: 3-1/2" L x 1-1/2" H x 2" D. Weight: 0.10 lbs. <br />Fike Reverse Polarity Module (CRPM) (P/N 10-2254)* <br />The reverse polarity module provides the ability for UL Remote Station supervision. This supervision is typically <br />performed with a direct, leased line connection. It interfaces to the main control board using four standoffs supplied with <br />the RPM. Dimensions: 3-1/2" L x 1-1/2"' H x 2" D. Weight: 0.08 lbs. <br />14 Button Remote Display Unit ( P/N 10-2646)* <br />The Fike fourteen button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The <br />FRD is provided with a 80 character, backlit display which performs two display functions. First, it duplicates information <br />provided by the control panel. Additionally the FRD has the capability of viewing system conditions such as alarm, <br />trouble, supervisory, etc. The FRD also includes six buttons (Enter, Escape, +j-, left/right arrow) that are used for <br />navigation through events as well as configuration of the device. Additionally it has eight programmable buttons that can <br />be configured for things such as reset, silence, acknowledge, drill, or process. A key lock is included for additional security, <br />access. Dimensions: 9-1/2" L, x 4" H x 2-1/4" D. W' eight: 0.5 lbs. <br />10 Button Remote Display Unit (P/N 10-2631)* <br />The Fike ten button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The FRD <br />is provided with a 80 character, backlit display which performs two display functions. First, it duplicates information <br />provided by the control panel. Additionally the FRD has the capability of viewing system conditions such as alarm, trouble, <br />supervisory, etc. The FRD also includes six buttons (Enter, Escape, +I-, left/right arrow) that are used for navigation <br />through events as well as configuration of the device. Additionally it has four dedicated buttons that perform the following <br />functions: drill, silence, acknowledge, and reset. A key lock is included for additional security access. Dimensions: 7-3/4" L <br />x 4" H x 2-1/4" D. Weight: 0.5 lbs. <br />2 Button Remote Display Unit (P/N 10-2630)* <br />The Fike two button remote display (FRD), provides remote annunciation of Fike's intelligent control panels. The FRD <br />is provided with an 80 character, backlit display which performs two display functions. First, it duplicates information <br />provided on the main control panel. Additionally, the FRD has the capability of mewing system conditions such as alarm, <br />trouble, supervisory, etc. Dimensions: 5-3/4" L x 4" 1I x 1-1/2" D. Weight 0.5 lbs. <br />See ordering information for individual data sheet that gives additional specifications Page 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.