Laserfiche WebLink
Installation <br />ASD-PL2F plug-in sensors use a separate base to <br />simplify installation, service, and maintenance. A <br />special tool allows maintenance personnel to plug-in <br />and remove sensors without using a ladder. <br />Mount the base on a box which is at least 1.5" (3.8 cm) <br />deep. Suitable mounting base boxes include: <br />• 4.0" (10.2 cm) square box. <br />• 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. <br />• Single -gang box (except relay or isolator bases). <br />• With B200S or B200SR base, mounted on a 4.0" <br />(10.2 cm) octagonal or square box. <br />• With B224RB or 1322461 base, mounted on a 3.5" <br />(8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or <br />square box. <br />NOTE: Because of the inherent supervision provided <br />by the SLC, end -of -line resistors are not required. <br />Wiring "T taps" or branches are permitted for Style 4 <br />(Class "B") wiring. <br />Sensor Spacing <br />Gamewell-FCI recommends that the spacing sensors <br />be used in compliance with NFPA 72. <br />Specifications <br />ASD-PL2F, ASD-PTL2F, ASD-PL2FR: <br />Dimensions: <br />2.1" (5.1 cm) height <br />Diameter: <br />4.1" (10.4 cm) installed in the B501 base <br />6.1" (15.5 cm) installed in the B21OLP base <br />Shipping Weight: <br />5.2 oz. (147 g) <br />Operating <br />ASD-PL2F: <br />Temperature: <br />32° F to 120` F (0` C to 49° C) <br />ASD-PTL2F: <br />32° F to 100• F (0° C to 38° C) <br />UL®-Listed <br />0-4000 ft./min. (1,219.2 m/min.), <br />Velocity Range: <br />suitable for installation in ducts. <br />Relative <br />Humidity: <br />10-93% (non -condensing) <br />Thermal Ratings: <br />Fixed -temperature setpoint <br />135° F (57° C) <br />Electrical Specifications <br />Voltage Range: 15 - 32 volts DC peak <br />Standby Current: (max. avg.)-. .0003 A @ 24 VDC <br />(One communication every 5 <br />seconds with LED blink enabled). <br />Maximum Alarm - <br />Current: .0065 A @ 24 VDC (LED) lit). <br />Bases and Options <br />B501 <br />Plug-in sensor base without flange <br />Dimensions: <br />4.1" (10.4 cm) diameter <br />B21OLP <br />Flanged mounting base <br />Dimensions: <br />6.1" (15.5 cm) diameter <br />B21OLPBP <br />Flanged mounting base bulk pack <br />Dimensions: <br />6.1" (15.5 cm) diameter <br />B224RB <br />Plug-in sensor base with auxiliary <br />Relay Base <br />relay, SPDT, rated 2 amps @ 30 VDC <br />(resistive). <br />Screw terminals: <br />Up to 14 AWG (2.0 mmz) <br />2 coil latching relay 1 Form C contact <br />UUCSA Rating: <br />0.9 A @ 125 VAC, inductive <br />0.9 A @ 110 VDC, inductive <br />3 A @ 30 VDC, resistive <br />Dimensions: <br />6.1" (15.5 cm) diameter <br />Maximum: 25 devices between <br />isolator bases. <br />B200S <br />Intelligent sensor sounder base <br />Dimensions: <br />6.875" (17.5 cm) diameter <br />B200SR <br />Standard sounder base, UL 8649th <br />Edition compliant, ULC Listed <br />Dimensions: <br />6.875" (17.5 cm) diameter <br />RA10OZ <br />Remote LED Annunciator <br />BCK-200 <br />Black detector covers (box of 10) <br />DNR <br />Duct smoke housing <br />GAMEWELL-FCI <br />12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 <br />9020-0617 Rev. J page 2 of 2 www.gamewell-fci.com <br />