'I'Gamewell <br />FIRE CONTROL <br />INSTRUMENTS <br />by Honeywell <br />Description <br />The Gamewell-FCI Velociti® Series, addressable output <br />relay control module (AOM-2RF) allows a Gamewell-FCI <br />analog addressable fire alarm control panel to switch dis- <br />crete relay contacts by code command. The relay provides <br />two isolated sets of Form-C contacts which transfer simul- <br />taneously. Circuit connections to the relay contacts are not <br />supervised by the module. <br />The Velociti® Series use a communication protocol that <br />substantially increases the speed of communication <br />between the SLC devices and certain Gamewell-FCI ana- <br />log addressable fire alarm control panels. These devices <br />operate in a grouped fashion. If one of the devices in the <br />group has a status change, the panel's microprocessor <br />stops the group poll and concentrates on the single device. <br />The net result produces a superior response speed up to <br />five times greater than earlier designs. <br />The AOM-2RF Module is designed for installation in the <br />signaling line circuit of any Gamewell-FCI analog address- <br />able fire alarm control panel. The module contains a panel <br />controlled LED. The AOM-2RF is designed to mount in a 4" <br />(10.16 cm) square junction box 2 1/8" (5.53 cm) deep. <br />Table 1 lists the relay contact ratings. <br />Current <br />Rating <br />Maximum <br />Voltage <br />Load <br />Description <br />Application <br />esls Ive <br />on Coded <br />2A <br />30 VDC <br />Resistive <br />Coded <br />0.9A <br />110 VDC <br />Resistive <br />Non -Coded <br />0.5A <br />125 VAC <br />Resistive <br />Non -Coded <br />0.5A <br />30 VDC <br />Inductive <br />(L/R=5ms) <br />Coded <br />1A <br />30 VDC <br />Inductive <br />(L/R=2ms) <br />Coded <br />0.5A <br />125 VAC <br />Inductive <br />(PF=.35) <br />Non -Coded <br />0.7A <br />75 VAC <br />Inductive <br />Non -Coded <br />Table 1: Relay Contact Ratings <br />UL® is a registered trademark of Underwriter's Laboratories Inc. <br />Velociti® Series is a registered trademark of Honeywell International Inc. <br />voinitiO Series <br />A0111=21F <br />Addressable Output Relay <br />Control Module <br />AOM-2RF <br />Features <br />• Listed under ULO Standard 864. <br />• Offers two sets of Form "C" contacts. <br />• Provides visual rotary, decimal switch addressing <br />(01-159). <br />• Includes a bicolor LED that flashes green whenever the <br />module is addressed, and lights steady red upon <br />activation." <br />• Designed as a compact size to allow easy installation. <br />Note: Only the red LED is operative in panels that do not operate <br />in Velociti mode. <br />Specifications <br />Supervisory current: <br />Alarm current: <br />Operating temperature <br />Relative humidity: <br />Dimensions: <br />.000375 amps. <br />.0065 amps. <br />32° to 120° F (0° to 49° C) <br />10 to 93% relative humidity <br />(non -condensing) <br />4 1 /2" H x 4" W x 1 1 /4" <br />(11.4 x 10.2 x 3.2 cm) <br />Ordering Information <br />Part Number Description <br />AOM-2RF Addressable output relay control module <br />SIGNALING <br />& <FM> MC w l <br />LISTED _.wD Appmved <br />S1913 3023594 219-02-E Vol. VI 7300-1703:0102 <br />IS0900111 GAMEWELL-FCI 1 <br />„�T; „" �1,� 12 Clintonville Road, Northford, CT 06472-1653 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 <br />Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. 1 <br />©2014 Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9020-0625 Rev. F page 1 of 1 <br />