Application <br />The S3 Series Fire Alarm and Life Safety System is an <br />easy -to -use intelligent fire alarm solution designed for the <br />small to mid -sized buildings. Analog technology delivers <br />the benefits of a simple system installation, while a user- <br />friendly interface makes panel operation and system main- <br />tenance quick and intuitive. <br />Smart Panel Programming <br />Using Boolean logic programming, the installer may cus- <br />tomize the system to precisely suit the needs of the build- <br />ing owner. Auto -programming allows the installer to <br />instantly locate all the devices on the SLC loop. <br />Simple, Intuitive Display <br />The front panel display provides a user-friendly interface <br />for the operator's control. A 4.3" (10.922 cm) color touch - <br />screen displays system status, event details and service <br />modes. On the front of the panel, six LEDs show the follow- <br />ing conditions. <br />• Fire Silenced <br />• Hazard (Gas or CO) AC Power <br />• Supervisory Trouble <br />Five custom programmable switches allow the user quick <br />access to common functions specific to the building like <br />device disable, output bypass and device status. <br />Perfect for Retrofits <br />The S3 Series is well -suited for retrofit applications. The <br />SLP provides a simple way to upgrade your fire protection <br />system. It is designed to be an upgrade solution for the leg- <br />acy FCI 7100 and Gamewell 602 Series panels. An added <br />feature is the SLP's EEOL. Using EEOL, the installers can <br />automatically identify the EOL for existing audible/visual <br />appliances. <br />Flexibility for Future Growth <br />The S3 Series can be expanded to add a second SLC loop <br />without replacing the entire system. Using the RPT-E3- <br />UTP Network Repeater, you can network up to 64 nodes <br />(122 nodes with the ANX node expander) using either <br />twisted -pair or fiber-optic. The built-in Ethernet port allows <br />the connection to the Gamewell-FCI's FocalPoint <br />Graphical Workstation. <br />Features (Continued) <br />• Offers an Ethernet port for programming, a variety of <br />system reports, and a FocalPoint Graphic Workstation <br />connectivity. <br />• Provides two fully -programmable Form-C contacts for <br />Fire, Trouble, and Supervisory. <br />• TimeCap - Saves time and date up to 48 hours without <br />any power or battery. <br />• Automatically adjusts to any NAC End -of -Line Resistor <br />(EOL) value (1k-55k ohm) for legacy audible/visual <br />appliances. <br />• Removable display can be used as a remote annunciator. <br />• Suitable for pre -action deluge applications. <br />Optional Accessories <br />DACT-E3 - Dialer <br />The Digital Alarm Communication Transmitter sends digital <br />signals over telephone lines to the central station. It con- <br />nects to the SLP through an RS-485 bus. Using the Con- <br />tact ID format, the DACT-E3 provides a four -digit account <br />code followed by the code/numbers listed below: <br />• Three -digit Event Code <br />• Two -digit Group Number <br />• Three -digit Contact Number <br />All codes are used to provide specific point identification. <br />The DACT-E3 is compatible with digital alarm communica- <br />tor receivers (DACRs) that receive the following signaling <br />formats: <br />• Contact ID SIA <br />• 3+1 4+2 <br />For more information, refer to the following data sheets: <br />DACT-E3 Data Sheet, P/N: 9020-0610 <br />FML-E3/FSL-E3 Data Sheet, P/N: 9021-60783 <br />RPT-E3-UTP - Network Repeater Card <br />The Network Repeater allows the SLP fire control panels to <br />connect to the broadband network from remote locations. It <br />connects to other networked units using unshielded, <br />twisted -pair wiring. The RPT-E3-UTP is available with two <br />add -on fiber modules: <br />• FML-E3 connects to the network using either 62.5/125 <br />micron multi -mode fiber. <br />• FSL-E3 connects to the network using 9/125 micron <br />single -mode fiber. <br />Refer to the RPT-E3-UTP Data Sheet, P/N: 9020-0609. <br />LCD-7100 - Remote Annunciator <br />The Remote serial display features an 80-character dis- <br />play. The LCD-7100 can be surface or flush -mounted on a <br />standard 4-gang electrical box. You can use up to five <br />LCD-7100 remote annunciators per SLP panel. For more <br />information, refer to the LCD-7100 Data Sheet, P/N: 9020-0486. <br />ASM-16 - Addressable Switch/LED Module <br />There are 16 programmable switches available to perform <br />any function the application requires. Each ASM-16 switch <br />has 3 LEDs fully programmable in red, yellow, and green. <br />These LEDs can be programmed to operate with a certain <br />button press or operate independently as a status signal <br />(e.g. ON, OFF, Activated, etc). <br />Up to 16 ASM-16 modules can be connected to the SLP <br />panel. For more information, refer to the ASM-16 Data <br />Sheet, P/N: 9020-0554. <br />ANU-48 - 48 LED Driver Unit <br />The ANU-48 provides output for eight remote panel <br />switches and 48 remote LEDs for use in a remotely located <br />UL® Listed annunciator enclosure. Up to 16 ANU-48 mod- <br />ules can be connected to the SLP panel. For more infor- <br />mation, refer to the ANU-48 Data Sheet, P/N: 9020-0596. <br />GAMEWELL-FCI <br />12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 <br />9021-60730 Rev. F page 2 of 4 www.gamewell-fci.com <br />