My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
6627 Fort King Rd (4)
Zephyrhills
>
Building Department
>
Building Plans
>
6627 Fort King Rd (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2025 5:02:45 PM
Creation date
2/25/2025 12:50:59 PM
Metadata
Fields
Template:
Building Plans
Street #
6627
Location
Fort King Rd
Contractor
Superior Fire Alarm
Building Plans - Permit #
17471
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Gamewell <br />FIRE CONTROL <br />INSTRUMENTS <br />by Honeywell <br />Description <br />The Gamewell-FCI, HPFF8 is a Notification Appliance Cir- <br />cuit (NAC) expansion panel designed to extend the power <br />capabilities of existing NACs and provide power for the <br />auxiliary devices. The HPFF8 connects to any 12 or 24V <br />Fire Alarm Control Panel (FACP) or stand alone. <br />The HPFF8 is available in 8.0 amps. It provides regulated <br />and filtered 24VDC power to each of the four NACs and an <br />auxiliary output. The NAC outputs are rated at 3.0 amps <br />each (the total output cannot exceed 8.0 amps). The auxil- <br />iary output is rated at 2.0 amps. This output is continuously <br />supplied, even in alarm, and therefore must be taken into <br />account for power supply loading and battery size calcula- <br />tions. <br />The NAC outputs may be configured as any of the follow- <br />ing: <br />• Four Class B (Style Y) <br />• Two Class A (Style Z) <br />• Two Class B and one Class A <br />• Four Class A with the optional HPP31076 Class A <br />adapter installed <br />These power supplies contain an internal Battery charger <br />capable of charging up to 26.0 amp -hour (AH) batteries. <br />The HPFF8 is mounted in lockable wall cabinet units that <br />can accommodate up to two (2), 18AH batteries. A multi - <br />pack option allows for up to four chassis mount units <br />installed in a single lockable SBB-D4 enclosure. These <br />chassis mount units have a "CM" suffix, HPFF8CM and <br />can accommodate two 12AH batteries. Power supplies are <br />available in either 120VAC/60 Hz or 240VAC/50 Hz. <br />One of the most challenging aspects of a retrofit applica- <br />tion is locating the existing End -of -Line (EOL) resistor. In <br />these applications that have EOL values, other than the <br />3.9k normally used with the HPFF8, a single resistor <br />matching the existing EOL can be used as a reference for <br />all the outputs. This feature speeds the installation and the <br />system checkout, because the actual EOL does not need <br />to be located and changed in the circuit. The reference <br />resistor must be within the range of 1.9k to 25k. <br />NPFF8 <br />NAC Expander/Power Supply <br />HPFF8 <br />Features <br />• Four (4) supervised notification application circuits <br />(NACs) capable of supplying +24VDC at 3.0 amp <br />maximum each <br />• NAC output circuits may be configured as any of the <br />following: <br />- Four Class B (Style Y) - Two Class B & one Class A <br />- Two Class A (Style Z) - Four Class A with the <br />optional HPP31076 Class A <br />adapter installed <br />• Four field -programmable operational modes <br />• 2.0 amp auxiliary continuously supplied output <br />• Two (2) fully supervised input/output control circuits <br />• Temporal coding and sync protocols compatible with <br />the following notification appliance brands: <br />- System Sensor - Faraday <br />- Gamewell - Amseco <br />- Cooper -Wheelock - Gentex <br />• Supervised AC input, battery voltage, auxiliary output, <br />charger, and earth ground faults <br />• Trouble indication for supervision of the following: <br />- NAC circuits - Auxiliary output <br />- AC input - Charger <br />- Battery voltage - Open contacts in the initiat- <br />- Earth ground faults by ing device signal inputs (for <br />individual status LED's FACP trouble notification) <br />• Separate Trouble and AC Fail Form-C relay Contacts <br />An ISO 9001-2000 Company <br />SIGNALJNG <br />LISTED FM <br />Y$1 <br />S24562 naaROvEo 7315-1637:0102 <br />GAMEWELL-FCI <br />12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 <br />Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. <br />©2010 by Honeywell International Inc. All rights reserved. www.gamewell-fci.com 9021-60521 Rev. B page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.