Laserfiche WebLink
<br />91 HEATING SYSTEM MULTIPLIERS (HSM) <br /> <br />CLIMJ.TE ZONES 4 5 6 <br /> <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS' <br />Central Heat HSPF 6.4 . 6.89 6.9 - 7.39 7.4 . 7.89 7.9 - 8.39 8.4 . 8.88 89 - Up <br />Pump Units COP 2.5 - 2.69 I 2.7 - 2.89 2.9 . 309 3.1 - 3,29 3.3 - 3.49 3.5 - 3.69 3.7 - Up . <br />HSM .50 .47 .44 .41 .39 37 <br />PTHP HSM .52 I .50 .47 .44 .41 .39 .37 <br />Electric Strio 10 <br />Gas & Other Fuels 10 (See Table 9J for Credit Multiplier) <br /> Minimums: Central Units-Air Source 2.7 COP (6.4 HSPF), Water Source 3.4 COP, <br /> Ground Water Source 3.2 COP PTHP 2.6. COP means Coefficient of Performance. <br /> <br />9J HEATING CREDIT MULTIPLIERS (HCM) <br /> <br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS <br />Attic Radiant Barrier HCM .98 <br />Multizone HCM .90 <br />Natural Gas AFUE 67 - .69 .70-.74 .75 - .79 .80.84 85 - .89 .90 - Up <br /> HCM 37 .35 33 .31 29 .27 <br />Other Fuels HCM .60 .58 54 .50 .47 .45 <br /> Where more than one credit is claimed, multiply HCM's together Enter product on page 4. <br /> AFUE means Annual Fuel Utilization Efficiencv <br /> <br />9K COOLING SYSTEM MULTIPLIERS (CSM) <br /> <br />SYSTEM TYPE COOLING SYSTEM MULTIPLIERS <br /> RATING 75 - , 8.0 I 8.5 - 9.0 - 9.5. 10.0. 10.5. 110. 115 - 12.0 <br />CENTRAL UNITS 7.9 8.4 8.9 9.4 9,9 10.4 10.9 11.4 119 & Up <br />(SEER/EER) CSM .40 (:38 ) .36 .34 ,32 .31 .30 .28 <br />PTAC & ROOM UNITS I <br />(EER) CSM .45 .43 .40 .38 .36 .34 .32 ,31 .30 .28 <br /> Minimums: Central Units-Air Cooled 7,8 EER (8.5 SEER). Ground Water Cooled 10.0 EER, <br /> EER means Enernv Efficiencv Ratio, SEER means Se.sonal Enerov Efficiencv Ratio, <br /> <br />9L COOLING CREOIT MULTIPLIERS (CCM) <br />SYSTEM TYPE <br /> <br />CREDIT MULTIPLI <br />.86 <br />.90 <br />,95 <br /> <br /> <br /> <br />Where more than one credit is claimed, multi I <br />9M HOT WATER MULTIPLIERS (HWM) <br /> <br /> <br />SYSTEM TYPE HOT WATER MULTIPLIERS <br />Electric EF .80 - .81 I .82 - .83 I 84 - .85 I .86 -87 I .88 - .90 I .91 - .93 I 94 - .96 I .97 & Up <br />Resistance HWM 3879 T 3785 I 3695 ' I 3609 1 3527 I 3411 1 3302 I 3200 <br /> EF .54 - .55 .56 - .57 .58 - .59 .60 - .61 62 - .63 64 -65 .66 &Up <br />Natural Gas HWM 1415 1364 1317 1273 1232 1194 1158 <br />Other Fuels HWM 2317 2234 2157 2085 2018 1955 1895 <br /> Water heaters must comply with prescriptive measures 01 Table 9A EF means Energy Factor <br /> <br />9N HOT WATER CREDIT MULTIPLIERS (HWCM) <br /> <br />SYSTEM TYPI HOT WATER CRE lllT MULTIPLIERS <br />Solar Water Heater SF .1 I 2 I .3 I .4 I .5 ,6 I .7 I .8 I .9 I 1.0 <br />HWCM ,9 I ,8 I .7 I .6 I .5 .4 I .3 I .2 1 .1 I ,0 <br />Heat Recovery Unit With Air.conditioner Heat pumn <br />HWCM ,62 (sR) <br />Dedicated Heat Pump EF 2.0-2.49 I 2.5-2,99 3,0-3.49 I 3,5 & Uo <br />HWCM .44 I .35 .29 I .25 <br />A HWM must be used in conjunction with all HWCM. See Table 9M, SF means Solar Fraction. EF means Energy Factor. <br /> <br />9P INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST (See Section 903.2(f)) <br /> <br />COMPONENTS REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 COMPLY WITH ALL INFILTRATION PRESCRIPTIVES ON TABLE 9A, <br />PRACTICE #2 COMPLY WITH PRACTICE #1 AND THE FOLLOWING: <br />Exterior Walls and Floors Ton nlate oenetrations sealed. Infiltration barrier installed, Sole olate/floor loint caulked or sealed, <br />Exterior Walls & Ceilinas Penetrations loints and cracks on interior surface caulked sealed or nasketed. <br />Ductwork Ductwork in unconditioned snace must be sealed. <br />Firenlaces Eauinned with outside combustion air doors and flue damners. <br />Exhaust Fans EQuipned with dampers, Combustion devices see 903.2m. <br />PRACTICE #3 COMPLY WITH PRACTICES #1 AND #2 AND THE FOLLOWING: <br />Ceilinas Infiltration barrier installed, <br />Interior Walts Too alate aenetrations sealed or ioints & cracks on interior walls caulked sealed or aasketed. <br />Recessed Liahts Sealed from conditioned soace & insulated from ventilated attic snaces, <br />Ductwork All ductwork located in conditioned soace, <br />Combustion Appliances Be in unconditioned space (except direct vent). Draw air from unconditioned space. Exhaust by.products <br />outdoors. Stoves see 903.2(f). <br /> <br />, For multipliers for other types 01 systems see section 904.9. <br /> <br />-6- <br />