My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
90-1074
Zephyrhills
>
Building Department
>
Permits
>
1990
>
90-1074
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2007 9:19:05 AM
Creation date
3/21/2006 10:09:45 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Building Department - Date
11/19/1990 12:00:00 AM
Permit #
90-1074
Building Department - Name
BLUICK,MARK
Address
37146 FOXRUN PL
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />FORM 900.A.89 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />SECTION 9 - RESIDENTIAL POINT SYSTEM METHOD <br />DEPARTMENT OF COMMUNITY AFFAIRS <br /> <br />OWNER: B <br /> <br /> <br />3..5Cf I <br /> <br /> <br />CLIMATE ~NES <br />CENTRAO! 5 6 <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br />PERMI <br />NO.: <br /> <br />NEW CONSTRUCTION <br />ADDITION 0 <br />MULTIFAMILY ATTACHED 0 <br />SINGLE-FAMILY DETACHED g <br /> <br />IF MULTIFAMILY, NUMBER OF CONDITIONED ~ sa. <br />UNITS COVERED BY OJ] FLOOR AREA ~ FT <br />THIS SUBMITTAL PREDOMINANT OJ 0 <br />EAVE OVERHANG . <br />CHECK IF THIS SUBMITTAL LENGTH . .' FT <br />REPRESENTS A WOR~Cj6E PORCH OVERHANG I-'Tl. I:l <br />CONDITION: ~ LENGTH LlLJ. U FT <br /> <br />GLASS AREA AND TYPE <br />CLEAR TINT,FILM,SOLAR SCREEN <br />SINGLE- r-T17"l.. ,I sa SINGLE- rTTTl sa, <br />PANE ~ fl PANE LL.LLJ FT.' <br />DOUBLE- rTTTl sa. DOUBLE- rTTTl sa, <br />PANE LL.LLJ fT. PANE LL.LLJ FT <br /> <br /> NET WALL AREA AND INSULATION <br />EXTERIOR MASONRY R EXTERIOR FRAME R EXTERIOR STEEL R = EXTERIOR LOG R <br />DililQ@W rn.[2 illIIJ so OJ illIIJ so OJ [IllJ] ~~. OJ <br /> FT FT <br />ADJACENT MASONRY R - ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R - <br />illIIJ SO. OJ.O illIIJ SO. OJ illIIJ SO OJ illIIJ SO OJ <br />FT FT FT FT <br /> <br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION <br />UNDER ATTIC R= SINGLE ASSEMBLY R= SLAB PERIMETER R= RAISED WD 0 CON 0 R= <br />~sa. W illIIJsa. OJ ~FT. ~ [IIIIJsa. OJ <br />FT FT. FT <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HDT WATER SYSTEM HOT WATER CREDITS <br />IN ~ENTRAL o ELECTRIC STRIP [B'HEAT ~ILlNG FANS ~ECTRIC: SO LAR : O.OJ <br />UNCONDITIONED <br /> o ROOM o NATURAL GAS PUMP o NATURAL GAS SF = <br />SPACE R = CROSS VENTILATION HEAT RECOVERY ICHECKI 0 <br />rn.~ o PACKAGE TERMINAL o ROOM UNIT OR o OTHER o WHOLE HOUSE FAN o OTHER FUELS <br />FUELS DEDICATED 0 <br />IN CONDITIONED AIR CONDITIONER PACKAGE TERMINAL o NONE o ATTIC RADIANT o NONE HEAT PUMP: .OJ <br />o NONE HEAT PUMP <br />SPACE R = ~H~PFI ~.aHJ BARRIER E F = <br />OJ.O SEER/EER = rn.~ o MULTIZONE EF = . [0 NUMBER OF ~ <br />BEDROOMS = <br /> <br />INFIL TRA TION ~ ~ []~121[jJ <br />0' PRACTICE USED X 100 = <br />#1 D #2 D #3 TOTAL AS-BUILT POINTS TOTAL BASE POINTS CALCULATED E.P.I, <br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. <br /> <br />DATE: <br /> <br /> <br />Review of the plans and specifications covered by this calculation indicates <br />compliance with the Florida Energy Code, Before construction is completed, this <br />building will be inspected f m~n acrordance with ~ i n 553,908 F,S. <br /> <br /> <br />In accordance with Section 553,907 F,S" I hereby certify that the plans <br />and specifications covered by this calculation are in compliance with the <br />Florida Energy Code. ) ..1 /' ____4-,"1 <br />-< . Q:)<. /~I ,.-' ,;, <br /> <br />DATE: <br /> <br />9A I PRESCRIPTIVE MEASURES (Must be met or exceeded bv all residences.l <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904,1 MAXIMUM OF 0,5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK. 1/ <br />EXTERIOR & 904,1 MAXIMUM OF 0.5 CFM PER SQ, FT, OF DOOR AREA INCLUDES SLIDING GLASS DOORS, SOLID CORE, /' <br />ADJACENT DOORS WOOD PANEL INSULATED OR GLASS DOORS ONLY, <br />EXTERIOR JOINTS 904.1 TO BE CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED. ./' <br />& CRACKS <br /> MUST SEAR LABEL INDICATING COMPLIANCE WITH ASHRAE STANDARD 90 OR COMPLY WITH EFFICIENCY AND <br />WATER HEATERS 904.2 STANDBY LOSS REQUIREMENTS, SWITCH OR CLEARLY MARKED CIRCUIT BREAKER (ELECTRIC), OR CUT-OFF ./ <br /> (GAS\ MUST BE PROVIDED. AN EXTERNAL OR BUILT-IN HEAT TRAP MUST BE PROVIDED, <br />SWIMMING POOLS 904,3 SPAS & HEATED POOLS MUST HAVE COVERS (EXCEPT SOLAR HEATED). NON-COMMERCIAL POOLS MUST <br />& SPAS HAVE A PUMP TIMER. GAS SPA & POOL HEATERS MUST. HAVE MINIMUM THERMAL EFFICIENCY OF 75%. <br />HOT WATER 904.4 INSULATION IS REOUIRED ONLY FOR RECIRCULATING SYSTEMS INCLUDING HEAT RECOVERY UNITS. IN SUCH CASES, PIPING HEAT LOSS <br />PIPES SHALL BE LIMITED TO 17.5 BTU/H/L1NEAR FOOT OF PIPE. ~ <br />SHOWER HEADS 904,5 WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE AT 80 PSIG. V <br />HVAC DUCT 903.2 CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS & LOCAL MECHANICAL CODES, DUCTS IN ~. <br />CONSTRUCTION 904.6 UNCONDITIONED SPACE MUST BE INSULATED TO MINIMUM R- 4,2 & JnINT~ MlJ~T BE SEALl=n <br />HVAC CONTROLS 904,7 SEPARATE READILY ACCESSIBLE MANUAL OR AUTOMATIC THERMOSTAT FOR EACH ~YSTEM. V./ <br />INSULATION 904.9 CEILINGS-MIN. R-19 COMMON WALLS-FRAME R-11 OR CBS R-3. FRAME COMMON CEILINGS & FLOORS R-11. if <br /> <br />-1- <br />
The URL can be used to link to this page
Your browser does not support the video tag.