Laserfiche WebLink
<br />FORM 1000-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 10 - Residential Perscriptive Compliance Method <br />Department of Community Affairs <br /> <br />Climate Z~s <br />CENTRA~ 6 <br /> <br />COMPLIANCE WITH SECTION 1() OF THE FLORIDA ENERGY EFFICIENCY CODE MAY BE DEMONSTRATED BY USE OF FORM1000A-91 FOR SINGLE AND MULTIFAMILY RESIDENCES OF 3 STORIES OR LESS <br />IN HEIGHT, AND ADDITIONS TO EXISTING RESIDENTIAL BUILDINGS, TO COMPLY, A BUILDING MUST MEET OR EXCEED ALL OF THE ENERGY EFFICIENCY PRESCRIPTIVES IN ANY ONE OF THE <br />PRESCRIPTIVE COMPONENT PACKAGES AND COMPLY WITH THE PRESCRIPTIVE MEASURES LISTED IN TABLE lOA OF THIS FORM, COMPLIANCE BY THIS METHOD WILL BE, IN MOST CASES, <br />EQUIVALENT TO AN EPI OF 100 POINTS OR LESS, AN ALTERNATIVE METHOD IS PROVIDED FOR ADDITIONS OF 600 SQUARE FEET OR LESS BY USE OF FORM 1 OOOC-91IF A BUILDING DOES NOT <br />COMPLY WITH THIS METHOD, IT MAY STILL COMPLY UNDER SECTION 9 OF THE CODE. <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br /> <br />NEW CONSTRUCTION 0 <br /> <br />ADDITION 0 <br /> <br />MULTIFAMILY ATTACHED 0 <br />(3 stories or less) <br />SINGLE,FAMILY DETACHED 0 <br /> <br />IF MULTIFAMILY, NUMBER OF <br />UNITS COVERED B, Y DIJ <br />THIS SUBMITTAL <br /> <br />CHECK IF THIS SUBMITTAL <br />REPRESENTS A WORST CASE <br />CONDITION 0 <br /> <br />BUILDER: <br />PERMITTING I8~L <br />OFFICE: <br />PERMIT <br />NO,: <br /> <br />CONDITIONED ~ SO <br />FLOOR AREA ~ FT <br />PREDOMINANT ~ ~ <br />[:~~f~ERHANG LJdJ. L9 FT <br /> <br />PORCH OVERHANG JTn--Q <br />LENGTH U2l.l.U FT <br /> <br /> <br />GLASS AREA AND TYPE <br />TINT,FILM.50LAR SCREEN <br />SINGLE, ITTTI SO <br />PANE UJ......LJ FT <br />DOUBLE, ITTTI SO DOUBLE, IITTl SO <br />PANE UJ......LJ FT PANE LLLl..J FT <br />FLOOR TYPE AND INSULATION <br />WOOD MASONRY <br />RAISED IT] 0 RAISED: - CD 0 <br />R =. R - . <br />COM~O~ [D. D COM~O~ COO <br /> <br />SLAB-ON, ru D <br />GRADE: R = LJU. <br /> <br />SI~AGNLt 1/19111 I ~~ <br /> <br />OWNER: <br /> <br />CLEAR <br /> <br />PERCENTAGE <br />OF GLASS ~ <br />TO FLOOR ~ % <br /> <br />WALL TYPE AND INSULATION <br />WOOD FRAME MASONRY <br />EXTERIO~ I~ D EXTERIO~ I ILl 0 <br />R-~. R-~. <br />ADJACENT 11'-( D ADJACE~ m 0 <br />R = L l iJ. R - . <br />COMMRO~ W. D COM~O~ m.D <br /> <br />CEILING TYPE AND INSULATION <br /> <br />COMPLIANCE B <br />PACKAGE <br />CHOSEN: <br /> <br />UNDER ATTI~o !:lliJ.O <br />COMMON R= m.o <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HOT WATER SYSTEM <br />IN m CENTRAL 0 NONE 0 ELECTRIC STRIP ~ ELECTRIC 0 NONE 0 SOLAR <br />UNCONDITIONED ~ HEAT PUMP <br />SPACE R = o ROOM 0 NATURAL GAS OTHER FUELS NATURAL GAS 0 HEAT RECOVERY <br />~[2J o PACKAGED TERMINAL 0 ROOM UNIT OR o NONE 0 OTHER FUELS o DEDICATED HEAT PUMP <br />IN CON n.IONED AIR CONDITIONER PACKAGED TERMINAL .ill] SF/EF = D.rn <br /> [E.[Q] HEAT PUMP <br />SPACE R 0 COP/HSPF/AFUE = ~.~ EF = <br />m.o SEER/EER = rn <br /> NUMBER OF BEDROOMS = <br /> <br /> <br />OWNER AGENT: <br /> <br />DATE <br /> <br />Review of plans and specifications covered by thi::; calculation indicates compliance with <br />the FlOrida Energy cOde~"construction IS completed, this b,U ilding,Will be inspected <br />for compliance In accordan ~,h Secti~.908, F.S. ... (' <br /> <br />BUILDING OFFICIAL (J.U..' 0 A..L.../\./,^--.;L~\L..~~ <br /> <br />DATE r~-, ,r;'" -W L, <br /> <br />TABLE 10A I MINIMUM REQUIREMENTS FOR All PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904,1 Minimum of 0,34 CFM per linear foot of operable sash crack (inCludes sliding glass doors), >< <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq, ft, of door area: solid core, wood panel, insulated or glass doors only, K" <br />ADJACENT DOORS <br />EXTERIOR 904,1 To be caulked, gasketed, weatherstripped or otherwise sealed, X <br />JOINTS & CRACKS <br />SOLE & TOP 903,2 Sole plates and penetrations through top plates of exterior walls must be sealed, X <br />PLATES <br />INFilTRATION 903,2 Infiltration barrier must be installed in exterior walls & raised wood floors, X <br />BARRIER <br />INTERIOR 903,2 All openings in interior surfaces of ceilings and exterior walls must be sealed, A <br />JOINTS/CRACKS <br />FIREPLACES 903.2 Fireplaces must have flue dampers, glass doors and outside combustion air intakes, ~1'1 <br />EXHAUST FANS 903,2 Exhaust fans vented to unconditioned space shall have dampers, except for combustion X <br /> devices with integral exhaust ductwork, <br />WATER HEATERS 904,2 Comply with efficiency requirements in Table 9-7A, Switch or clearly marked circuit breaker (electric) K <br /> or cutoff (gas) must be provided. External or built-in heat trap required. <br />SWIMMING 904,3 Spas & heated pools must have covers (except solar heated), Non,commercial pools must have a AJfl <br />POOLS & SPAS pump timer, Gas spa & pool heaters must have minimum thermal efficiency of 78%, <br />HOT WATER 904.4 Insulation is required only for recirculating systems, including heat recovery units. In such cases, X <br />PIPES piping heat loss shall be limited to a maximum of 17,5 BTUH per linear foot of pipe. <br />SHOWER HEADS 904,5 Water flow must be restricted to no more than 3 callons per minute at 80 PSIG, 'J<.. <br />HV AC DUCT 904,6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, k <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904,6, Ducts in unconditioned <br />INSULATION & space and air handlers located in attics must be insulated to a minimum R-4,2 (R-6 after 1/1/92). <br />INSTAllATION <br />HV AC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system, 'A <br /> <br />-1 - <br />