Laserfiche WebLink
<br />FORM 90Q-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 9 - Residential Point System Method <br />Department of Community Affairs <br /> <br />Climate Zones <br />CENTRA~5 6 <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br /> <br />NEW CONSTRUCTION <br />ADDITION 0 <br />MULTIFAMILY ATTACHED 0 <br />SINGLE-FAMILY DETACHED 0 <br /> <br />IF MULTIFAMILY, NUMBER OF CONDITIONED ~ sa. <br />UNITS COVERED BY OJ] FLOOR AREA ~ Fl <br />THIS SUBMITTAL: PREDOMINANT OJ 0 <br />EAVE OVERHANG <br />CHECK IF THIS SUBMITTAL LENGTH . FT. <br />REPRESENTS A WOR~CA~ PORCH OVERHANG OJ 0 <br />CONDITION: b:1' LENGTH . FT <br /> <br /> <br />50 60 <br /> <br />OWNER:l<).-A-. N~ <br /> <br />PERMIT <br />NO.: <br /> <br />GLASS AREA AND TYPE <br />CLEAR TINT,FILM,SOLAR SCREEN <br />SINGLE- nTTl sa SINGLE- I sa, <br />PANE ~ FT PANE T. <br />DOUBLE- nTTl sa. DOUBLE- nTTl sa. <br />PANE ~ Fl PANE ~ Fl <br /> <br /> NET WALL AREA AND INSULATION <br />EXTERIOR MASONRY R = EXTERIOR FRAME R = EXTERIOR STEEL R = EXTERIOR LOG R - <br />DIID so. OJ.O ~~ [ill] DIIDSQ OJ DIIDso. OJ <br /> FT FT FT <br />ADJACENT MASONRY R = ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R = <br />DIID so OJ.O DIID so OJ DIIDso OJ DIIDso OJ <br /> FT. FT Fl FT <br /> <br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION <br />UNDER ATTIC R = SINGLE ASSEMBLY R = SLAB PERIMETER R= RAISED WD 0 CON 0 R= <br />~sa. ~ DIIDsa. OJ ~Fl ~ DIIDsa. OJ <br /> Fl Fl Fl <br />DUCTS CO!)LING SYSTEM HEATING SYSTEM HVAC CREDITS HOT WAtfR SYSTEM HOT WATER CREDITS <br />IN &?CENTRAL D ELECTRIC STRIP ~T D CEILING FANS ~ECTRIC SOLAR: D.OJ <br />UNCONDITIONED <br />D~r~ D ROOM D NATURAL GAS PUMP D CROSS VENTILATION D NATURAL GAS SF = <br /> D OTHER HEAT RECOVERY ,CHECK' 0 <br />D PACKAGE TERMINAL D ROOM UNIT OR D WHOLE HOUSE FAN D OTHER FUELS <br /> FUELS DEDICATED D <br />IN CONDITIONED AIR CONDITIONER PACKAGE TERMINAL D NONE D ATTIC RADIANT D NONE HEAT PUMP: .OJ <br />D NONE HEAT PUMP <br />SPACE R = BARRIER E.F = <br />OJ.O rn.~ COPfHSPFf ~ ~ D MULTIZONE EF = .[0 NUMBER OF ~ <br />SEER/EER = AFUE = . BEDROOMS = <br />INFIL TRA TION ~ ~ I I ~ILf.[Q] <br />PRACTICE USED X 100 = <br />o 1/1 ~ 0 1/3 TOTAL AS.BUIL T POINTS TOTAL BASE POINTS CALCULATED E.P.I. <br /> CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. <br /> <br /> I hereby certify tha~;~an~ and spec''t,ns covered by the calculation are in compliance with the Review of plans and specifications covered by this calculation indicates compliance With <br />Florida Energy Code. ~.. / (. the FlOrida Energy Code. B~~ction is completed, this building will be inspected <br />PREPARED BY: / / ,/ />'''_.:,,~ DATE:':;"" -:.-\ '.; r~ / for compliance in accordance' ..ion ~. F,S, - L <br />I hereby certify that thi~~inA l ry cO".'J'"aJ; with the Florida Energy Code, BUilDING OFFICIAL: x.. ~ , ~~.... <br />~.~ -~~.~. ~:/ ~- (2-.! 91 <br />OWNER AGENT: / /l /. '-;- .:. .:?./ {. ,'//- .. DATE: DATE: <br />9A I PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904.1 Maximum of 0.34 CFM per linear foot of operable sash crack (includes sliding glass doors). <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area: solid core, wood panel, insulated or glass doors only. <br />ADJACENT DOORS <br />EXTERIOR JOINTS 904.1 TD be caulked, gasketed, weatherstripped or otherwise sealed. <br />& CRACKS <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (gas) must be provided. External or built-in heat trap reQuired. <br />SWIMMING POOLS 904.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a <br />& SPAS pump timer. Gas spa & pool heaters must have minimum thermal efficiency of 78%. <br />SHOWER HEADS 904.5 Water flow must be restricted to no more than 3 aallons per minute at 80 PSIG. <br />HV AC DUCT 904.6 All ducts. fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned <br />INSULATION space and air handlers located in attics must be insulated to a minimum R-4.2 (R-6 after 1/1/92). <br />& INSTALLATION <br />HVAC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. <br />INSULATION 904.9 Ceilings-Min. R-19. Common Walls-Frame R-11 or CBS R-3. Common Ceilings & Floors R-11. <br /> <br />- 1 - <br />