Laserfiche WebLink
<br /> <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 500-A-91 SECTION 5 · BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH ~ <br />Non-Residential Buildings ADMINISTERE BY THE DEPARTMENT OF COMMUNITY AFFAIRS <br />Residential Buildings over 3 stories (J~"",j ALL CLIMATE ZONES <br /> <br />ZONE: <br />BUILDING CLASSIFICATION S : <br />BUILDING PERMIT NO.: <br />PERMITTING OFFICE: <br />JURISDICTION NO.: <br /> <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA <br />Concrete (CBS) ,)1 ,':;'"'.J v Under attic t31 '!t. Jd Slab-onijrade lfl tSU> Wood Single, wall 175r' )).6.$ <br />Wood frame Single Assembly Raised Wood Metal Double, wall <br />Metal frame Other: Raised concrete Insulated .tiC ~j' ( '" Single, roof <br />Insulation R-value ~.Ji Insulation R-value ~ Insulation R-value Other Double, roof <br /> SYSTEMS INFORMATION <br />AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTU I H TYPE <br />Unitary & Heat Pump .5",)- Central & Heat Pump Electric ~ <br /><65,000 Blu/h LSEER < 65,000 Btu 1 h _ HSPF - Resistance <br />,,65,000 Blu/h EER IPLV 2: 65,000 Btu/h _COP - Dedicated Heat Pump 0 <br /> - - ~ Water cooled _COP Gas <br /> - <br />Water Cooled - EER - IPLV ~ Evaporatively cooled _COP Natural 0 <br /> - <br />Evaporatively Cooled - EER ~ Electric resistance -L COP LPG 0 <br /> - <br />PTAC - EER ~ Gas/Oil (circle one) Oil 0 <br />Chillers COP IPLV < 225,000/300,000 Btu/h _AFUE - HRU 0 <br /> - - ~ 2: 225,000/300,000 Btu 1 h Et <br />Other: Other: <br />LIGHTING 3 ~ OC) Lighting Budget (from TIlble 5-13): -- <br />Total Lighting Wattage Total Conditioned Floor Area /~ '/)-0 - Watts/sq. ft: I, &1 S <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Windows 502.4 Maximum of .37 cfm per linear foot of operable sash crack. .)C- <br />Doors 502.4 Maximum of 1.25 cfm per square foot of door area. K <br />Joints/Cracks 502.4 To be caulked, gasketed, weatherstripped or otherwise sealed. -,.. <br />Reheat 503.3 Supply air restricted to set cold/hot deck temperature to meet load of worst case zone. Resistance reheat prohibited. ) <br />Ventilation 503.4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. ~ <br />HV AC Efficiency 503.4 Minimum efficiencies-Heating: Tables 5-4, 5-5 & 5-6. Cooling: Tables 5-7A, 5-7B, 5-8 & 5-9. ) <br />Transport Energy 503.5 Minimum of 8.0. i" <br />Balancing 503.6 Provide means for balancing HVAC air system & water distribution system. ~ <br />HV AC Controls 503.7 Separate readily accessible manual or automatic thermostat for each system. /" <br />HV AC Ducts 503.8 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, .,... <br /> 503.9 insulated and installed in accordance with the criteria of sections 503.8, 503.9 and 503.10. <br /> 503.10 <br />Piping Insulation 503.11 In accordance with Table 5-10. '7' <br />Water Heaters 504.2 Automatic electric storage water heaters ~120 gallons and gas & oil-fired storage water heaters <br /> ~ 75,000 Btu/h shall meet performance minimums in Table 5-11. Larger sized water heaters shall ..,.... <br /> meet minimums in Table 11-1 of Standard RS-9 after 1/1/92. <br />Swimming Pools 504.2 Spas & heated pools must have covers. Non-commercial pools must have pump timer. Nt- <br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%. <br />Hot Water Pipe 504.4 Piping heat loss is limited to 17.5 Btu/h linear foot of pipe for recirculating systems (see Table 15-12). 1/1+ <br />Insulation <br />Water Fixtures 504.5 Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3.5 gallon flush. '" <br /> Public lavatory fixture maximum flow of .5 gpm or .5 gallon if has self-closing valve. <br />Lighting 505.1 Lighting power budgets are listed in Table 5-13. Minimum Ballast Efficacy Factors are listed in Table 5-14. -r-- <br />Uo wall Allowable 1/ ~'1. Uo wall Actual f ./ '^ If complying under the provisions of S, 502,1, enter the combined Uo values for the entire envelope <br /> dO .~ <br />Uo roof! ceiling Allowable Uo roof 1 ceiling Actual N'~ in this section, <br />Uo floor Allowable p~ Uo floor Actual Uo envelope Allowable Uo envelope Actual <br />OTTV wall Allowable 1..!:ilr..- OTTV wall Actual 'It,~>v <br />OTTV roof 1 ceiling Allowable A/rr OTTV roof! ceiling Actual A://I <br /> <br />Compliance with Section 5 was demonstrated by a Prescriptive Measures methodology: <br />D 508.0 (a) Detached commercial buildings D 508.0 (b) Skyboxes or sports stadium buildings <br />less than 100 square feet. that are used only seasonally. <br /> <br /> <br />OWNER/AGENT: <br /> <br />DATE: <br /> <br />