<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />FORM 500-A-91 SECTION 5 . BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH
<br />Non.Re.ldentlal Building. ADMI IST~eD BY THE DEPARTMENT OF COMMUNITY AFFAIRS .
<br />Re.ldentlal Buildings over 3 .torle. ~JJjj C-.- ALL CLIMATE ZONES
<br />ZONE:
<br />BUILDING CLASSIFICATION S :
<br />BUILDING PERMIT NO.:
<br />PERMITTING OFFICE:
<br />JURISDICTION NO.:
<br />
<br />
<br /> BUILDING INFORMATION
<br />WAL :.s ROOF/CEILING FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete (CBS) " -'61'5 Under attic 1:1\3 /..J <f:( Slatxm'9rade -D N'S~ Wood Single, wall I~ -/0 -,
<br />Wood frame Single Assembly Raised Wood Metal Double, wall
<br />Metal frame Other: . Raised concrete Insulated ,It -~ ( .(.. Single, roof
<br />Insulation R-value IlA' Insulation R-value , . ',:i' ' Insulation R-value Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br />AIR CONDITIONER HEATING SYSTEM HOT WATI!R
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTU/H TYPE
<br />Unitary & Heat Pump 2.S'" Central & Heat Pump Electric
<br /><65,000 Btu1ll ~SEER - < 65,000 Btulh _ HSPF - Resistance ~
<br />,.65.000 BtuIh _EER IPlV 2: 65,000 Btu 1 h _COP - Dedicated Heat Pump 0
<br />- -
<br />Water Cooled EER IPlV Water cooled _COP - Gas
<br />- - - Evaporatlvely cooled _COP Natural 0
<br /> -
<br />Evaporatively Cooled - EER - Electric resistance -L- COP LPG 0
<br /> -
<br />PTAC _EER - Gas 1011 (circle one) Oil 0
<br />Chillers _COP - IPlV - < 225,0001300,000 Btulh _ AFUE - HRU 0
<br />Other: 2: 225,0001300,000 Btu I h Et Other:
<br />LIGHTING ~O I\{ ~L1ghtlng Budget (from Table 5-13): -.:2
<br />Total Lighting Wattage : Total Conditioned Floor Area - Wattslsq. ft: ~~u
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />COMPONENTS SECTION REQUIREMENTS CHECK
<br />Windows 502.4 Maximum of .37 elm per linear foot of operable sash crack. '/-.
<br />Doors 502.4 Maximum of 1.25 cfm per square foot of door area. \j
<br />Joints/Cracks 502.4 To be caulked, gasketed, weatherstripped or otherwise sealed. 'v
<br />Reheat 503.3 Supply air restricted to set coldthot deck temperature to meet load of worst case zone. Resistance reheat prohibited. x:
<br />Ventilation 503.4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. ...r
<br />HV AC Efficiency 503.4 Minimum efficiencies.Heating: Tables 5-4, 5-5 & 5-6. Cooling: Tables 5-7A, 5-7B, 5-8 & 5-9. -lC
<br />Transport Energy 503.5 Minimum of 8.0. ..c
<br />Balancing 503.6 Provide means for balancing HVAC air svstem & water distribution system. -r
<br />HV AC Controls 503.7 Separate readily accessible manual or automatic thermostat for each system. v
<br />HVAC Ducts 503.8 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed,
<br /> 503,9 insulated and installed in accordance with the criteria of sections 503.8, 503.9 and 503.10, ^'
<br />. 503.10 ..
<br />Piping Insulation 503.11 In accordance with Table 5-10. )-.
<br />Water Heaters 504.2 Automatic electric storage water heaters 50120 gallons and gas & oilolired storage water heaters r
<br /> 50 75,000 Btuth shall meet performance minimums in Table 5-11. Larger sized water heaters shall
<br /> meet minimums In Table 11-1 of Standard RS-9 after 1/1/92.
<br />Swimming Pools 504.2 Spas & heated pools must have covers. Non-commercial pools must have pump timer. Nil-
<br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%.
<br />Hot Water Pipe 504.4 Piping heat loss is limited to 17,5 Btuth linear foot of pipe for recirculating systems (see Table 5-12). !fill
<br />Insulation
<br />Water Fixtures 504.5 Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3.5 gallon flush. ^'
<br /> Public lavatory fixture maximum flow of .5 gpm or .5 gallon if has self-closing valve.
<br />Lighting 505.1 Lighting power budgets are listed In Table 5-13. Minimum Ballast Efficacy Factors are listed in Table 5-14. 'I-
<br />
<br />Uo wall Allowable I
<br />Uo roof! ceiling Allowable
<br />Uo floor Allowable
<br />
<br />OTTV wall Allowable
<br />OTTV roof 1 ceiling Allowable
<br />
<br />. I
<br />/I. / 4-
<br />
<br />Uo wall Actual '
<br />Uo roof! ceiling Actual
<br />Uo floor Actual
<br />
<br />II complying under the provisions of S. 502.1, enter the combined Uo values for the entire errvetope
<br />in this section.
<br />Uo envelOpe Allowable Uo envelope Actual
<br />
<br />OTTV wall Actual
<br />OTTV roof! celli
<br />
<br />
<br />Compliance with Section 5 was demonstrated by a Prescriptive Measures methodology:
<br />O 508.0 (a) Detached commercial buildings 0 508.0 (b) Skyboxes or sports stadium buildings
<br />less than 100 square feet. that are used only seasonally,
<br />
<br />I hereby certify that t
<br />with the Florida Ene
<br />PREPARED BY:
<br />I hereby certify tha
<br />
<br />OWNER/AGENT:
<br />
<br />
<br />DATE:~"")-"'~ (
<br />compliance with the Florida Energy Code.
<br />
<br />DATE:
<br />
<br />Revl_ of plans and specifications covered by this calculation indicates compliance with !he
<br />Florida Energy Code. Before construction is completed, this bul1dlng wi be Inspected for
<br />compliance in accordance w ion 553. F.S. -