Laserfiche WebLink
<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />FORM 500-A-91 SECTION 5 . BUILDING DESIGN BY COMPONENT PERFORMANCE APPROACH <br />Non.Resldentlal Buildings ADMINISTERED BY THE DEPARTMENT OF COMMUNITY AFFAIRS <br />Residential Buildings over 3 stories ALL CLIMATE ZONES <br /> <br /> <br />ZONE: L,-/ <br /> <br />BUILDING CLASSIFICATION S : <br /> <br />BUILDING PERMIT NO.: I") , J <br />~ <br />PERMITTING OFFICE:' <br /> <br />JURISDICTION NO.: <br /> <br /> <br />~f <br /> <br />PROJECT NAME: <br />ADDRESS: ..s1" :; <br />CITY ZIP CODE: "':) ~ <br />BUILDER: <br />OWNER: <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA <br />Concrete (CBS) I..n tiJ )'''f Under attic I rut );.oJ Slab-<>n..grade It- 'J-t )--1 Wood II).i.J; Single, wall .If 3~ <br />Wood frame Single Assembly \. Raised Wood Metal Double, wall <br />Metal frame Other: Raised concrete Insulated Single, roof <br />Insulation R-value Insulation R-value Insulation R-value Other Double, roof <br /> <br /> SYSTEMS INFORMATION <br />AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTU/H TYPE <br />Unitary & Heat Pump ~ Central & Heat Pump Electric 12f' <br /><65,000 Btulh ~,(gEER < 65,000 Btu I h _ HSPF - Resistance <br />;,,65,000 Btu/h EER IPLV ~ 65,000 Btu I h _COP - Dedicated Heat Pump 0 <br /> - - - Water cooled _COP Gas <br /> - <br />Water Cooled - EER - IPLV - Evaporatively cooied _COP IW) Natural 0 <br />Evaporatively Cooled - EER - Electric resistance ---I--- COP LPG 0 <br />PTAC - EER - Gas 10il (circle one) Oil 0 <br />Chillers COP IPLV < 225,000/300,000 Btu/h _ AFUE - HRU 0 <br /> - - - ~ 225,000/300,000 Btu/h Et <br />Other: Other: <br />LIGHTING :5 II '(D Lighting Budget (from Table 5-13): ':1 <br />Total Lighting Wattage Total Conditioned Floor Area :J..D ,. I - Watts/sq. It: '~6. i/ <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Windows 502.4 Maximum of ,37 cfm per linear foot of operable sash crack. Y <br />Doors 502.4 Maximum of 1 ,25 cfm per square foot of door area. X <br />Joints/Cracks 502.4 To be caulked, gasketed, weatherstripped or otherwise sealed. )/' <br />Reheat 503.3 Supply air restricted to set cold/hot deck temperature to meet load of worst case zone, Resistance reheat prohibited, y <br />Ventilation 503.4 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. '')0.,. <br />HV AC Efficiency 503.4 Minimum efficiencies,Heating: Tables 5-4, 5-5 & 5-6. Cooling: Tables 5,7A, 5-7B, 5-8 & 5-9, ~ <br />Transport Energy 503.5 Minimum of 8.0. 7 <br />Balancing 503.6 Provide means for balancing HV AC air system & water distribution system. '" <br />HV AC Controls 503.7 Separate readily accessible manual or automatic thermostat for each system, i' <br />HV AC Ducts 503.8 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, <br /> 503.9 insulated and installed in accordance with the criteria of sections 503.8, 503.9 and 503.10. 'f <br /> 503.10 <br />Piping Insulation 503,11 In accordance with Table 5-10, " <br />Water Heaters 504.2 Automatic electric storage water heaters ~120 gallons and gas & oil,fired storage water heaters <br /> ~ 75,000 Btu/h shall meet performance minimums in Table 5-11. Larger sized water heaters shall '" <br /> meet minimums in Table 11-1 of Standard RS-9 alter 1/1/92, <br />Swimming Pools 504,2 Spas & heated poois must have covers. Non-commercial pools must have pump timer. P..;f <br />& Spas Gas spa & pool heaters must have minimum thermal efficiency of 78%. <br />Hot Water Pipe 504.4 Piping heat loss is limited to 17.5 Btu/h linear foot of pipe for recirculating systems (see Table 5,12). 'f <br />Insulation <br />Water Fixtures 504.5 Water flow restricted to maximum of 3 gpm at 80 psig; toilets maximum 3,5 gallon flush. y... <br /> Public lavatory fixture maximum flow of ,5 gpm or .5 gallon if has self-closing valve. <br />Lig hti ng 505.1 Lighting power budgets are listed in Table 5,13. Minimum Ballast Efficacy Factors are listed in Table 5,14, l" <br /> <br />Uo wall Allowable t.....~ Uo wall Actual . :J.-'1 If complying under the provisions of S. 502,1, enter the combined Uo values for the entire envelope <br />Uo rooft ceiling Allowable '. -ro Uo rooft ceiling Actual ~'A in this section, <br />Uo floor Allowable Uo floor Actual Uo envelope Allowable U() envelope Actual <br />OTTV wall Allowable ~n~ OTTV wall Actual ~ "'" <br />OTTV rooft ceiling Allowable OTTV roof / ceiling Actual <br /> <br />Compliance with Section 5 was demonstrated by a Prescriptive Measures methodology: <br />D 508.0 (a) Detached commercial buildings D 508.0 (b) Skyboxes or sports stadium buildings <br />less than 100 square feet. that are used only seasonally. <br /> <br /> <br />OWNER/AGENT: <br /> <br />DATE: <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with the <br />Florida Energy Code, Before construction is completed, this building will be inspected for <br />compliance in accord, a~';!1:;on 553908, FtJ <br />BUILDINGlfICIAL:~ ~.I..A..A."'--" = <br /> <br />DATE: -..:i- <br />