Laserfiche WebLink
<br />*~ <br /> <br />DESIGN FORUM INC. <br />POST OFFICE BOX 2783 <br />TAMPA, FLORIDA <br /> <br />November 3, 1991 <br /> <br />Mr. Kevin Roberts <br />General Home Development <br />817 South 98 Bypass <br />Dade City, Florida33525 <br /> <br />re: Silver Oak Condos <br /> <br />Dear Kevin, <br />as you conveyed to me via telephone last week, the conditionon:oB roof <br />appears to satisfy the Standard Building Code requirements if the following <br />stipulations are provided; <br /> <br />The stacked plywood sheathing must be a mlnlmun <br />thickness of 15/32 in. thick (case 5 stack bond) <br />with 10d nails spaced at 6 in. on center at <br />supported edges which shall not exceed 2'-0" o.c. <br /> <br />This condition will support a shear value of 215 lbs. per linear foot <br />which exceeds the actual shear value of 126 lbs. per linear feet. <br />If you have any questions ,please call at your convenience. <br /> <br />~::~~ .. /1 <br />tlni;if L~II <br /> <br />, /J2 <br />