Laserfiche WebLink
<br />FORM 900-A-91 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Section 9 - Residential Point System Method <br />Department of Community Affairs <br /> <br />Climate ~~es <br />CENTRAfY 5 6 <br /> <br />OWNER: <br /> <br /> <br />~ <br /> <br />IF MULTIFAMILY, NUMBER OF CONDITIONED ~ SQ. <br />UNITS COVERED BY [ill FLOOR AREA ~ Fl <br />THIS SUBMITTAL: PREDOMINANT rn [eJ <br />EAVE OVERHANG 0 <br />CHECK IF THIS SUBMITTAL LENGTH . FT. <br />REPRESENTS A WORST CASE PORCH OVERHANG c;TIl 0 <br />CONOITION D LENGTH ~. ~ FT. <br /> <br />BUILDER: <br />PERMITTING <br />OFFICE: <br /> <br />PERMIT; ;' <br />NO.: <br /> <br /> <br />GLASS AREA AND TYPE <br />CLEAR TINT,FILM,SOLAR SCREEN <br />SINGLE- [[ill SQ. SINGLE- n;r:r.:::tO SQ. <br />PANE FT. PANE ~ FT. <br />DOUBLE- [[ill SQ. DOUBLE- [[ill SQ. <br />PANE FT. PANE FT. <br /> <br />PROJECT NAME <br />AND ADDRESS: <br /> <br />NEW CONSTRUCTION <br />ADDITION D <br />MULTIFAMILY ATTACHED D <br />SINGLE-FAMILY DETACHED J21' <br /> <br /> NET WALL AREA AND INSULATION <br />EXTERIOR MASONRY R - EXTERIOR FRAME R = EXTERIOR STEEL R = EXTERIOR LOG R = <br />ITIIIJ SQ. m.o ~SQ. [ill] ITIIIJ SQ m [IIIIJ ~~. m <br /> Fl FT. FT. <br />ADJACENT MASONRY R - AOJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG R = <br />ITIIIJ SQ. m.o ITIIIJ SQ. m ITIIIJ SQ. m ITIIIJ SQ m <br /> Fl FT FT FT. <br /> <br /> CEILING AREA AND INSULATION FLOOR TYPE AND INSULATION <br />UNDER ATTIC R - SINGLE ASSEMBLY R - SLAB PERIMETER R- RAISED: WD 0 CO~ R= <br />~SQ. ~ ITIIIJSQ. m ~FT. rn [IIIIJSQ. m <br />FT. FT. FT. <br /> <br />DUCTS COOLING SYSTEM HEATING SYSTEM HVAC CREDITS HOT WATER SYSTEM HOT WATER CREDITS <br />IN ~ENTRAL D ELECTRIC STRIP ~EAT ;;5rCEILlNG FANS I~LECTRIC SOLAR: o.m <br />UNCONDITIONED <br />SPACE R = D ROOM D NATURAL GAS PUMP t21 CROSS VENTILATION D NATURAL GAS SF. = HEAT RECOVERY iCHECKI ~ <br />rn.~ D PACKAGE TERMINAL D ROOM UNIT OR D OTHER D WHOLE HOUSE FAN D OTHER FUELS <br />FUELS DEDICATED <br />AIR CONDITIONER PACKAGE TERMINAL HE:~P~MP: 0 . m <br />IN CONDITIONED D NONE HEAT PUMP D NONE D ATTIC RADIANT D NONE <br />SPACE R = BARRIER <br />m.D SEER/EER = [BJ.lfI COP I HSPF I ~.~ D MULTIZONE EF = .rl~ NUMBER OF rn <br />AFUE = BEDROOMS = <br /> <br />INFll TRA TION ~ ~ DlliJ. ~ <br />PRACTICE USED X 100 = <br />D #1 ~#2 D #3 TOTAL AS-BUilT POINTS TOTAL BASE POINTS CALCULATED E.P.I. <br />CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. <br /> <br /> <br />covered by the calculation are in compliance with the <br />I <br /> <br />PREPARED BY: <br /> <br />Cj_ I '" <br />DATE:~) . 1/ <br /> <br />Review of plans and specifications covered by this calculation indicates compliance with <br />the Florida Energy Code. Befor constructi completed. this building ~ill be inspected <br />for compliance in accordan wi Sect; 3.908. F.S. <br /> <br /> <br />I hereby certify that this building is' compliance ,with}he Florida Energy Code. t:' _ <br />OWNER AGENT,/' J;;..C(;...fi.r (.I '-! "': "kc~~ DATE: 1- I!), -7/ DATE: <br /> <br /> <br />9A I PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />WINDOWS 904.1 Maximum of 0.34 CFM oar linear foot of operable sash crack (includes slidino olass doors). <br />EXTERIOR & 904.1 Maximum of 0.5 CFM per sq. ft. of door area: solid core, wood panel, insulated or glass doors only. <br />ADJACENT DOORS <br />EXTERIOR JOINTS 904.1 To be caulked, gasketed, weatherstripped or otherwise sealed. <br />& CRACKS <br />WATER HEATERS 904.2 Comply with efficiency requirements in Table 9-7A. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (gas) must be orovided. External or built-in heat trap required. <br />SWIMMING POOLS 904.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a <br />& SPAS pump timer. Gas spa & 0001 heaters must have minimum thermal efficiency of 78%. <br />SHOWER HEADS 904.5 Water flow must be restricted to no more than 3 callons per minute at 80 PSIG. <br />HVAC DUCT 904.6 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br />CONSTRUCTION, sealed, insulated and installed in accordance with the criteria of Section 904.6. Ducts in unconditioned <br />INSULATION space and air handlers located in attics must be insulated to a minimum R-4.2 (R-6 after 1/1/92). <br />& INSTAllATION <br />HV AC CONTROLS 904.7 Separate readily accessible manual or automatic thermostat for each system. <br />INSULATION 904.9 Ceilings-Min. R-19. Common Walls-Frame R-11 or CBS R-3. Common Ceilings & Floors R-11. <br /> <br />- 1 - <br />