<br />91 I;E'ATING SYSTEM MULTIPLIERS (HSM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />SYSTEM TYPE HEATING SYSTEM MULTIPLIERS <br />-- 7.9 - 8.39 8.4 - 8.89 8.9 - 9.39 9.4 - 9.89 <br />Central Heat HSPF 6.4 . 6.79 6.8 - 6.89 6.9 - 7.39 7.4 - 7.89 <br />Pump Units HSM .53 .50 .49 .46 .43 .41 .38 .36 <br /> HSPF 9.9 - 10.39 10.4 -10.89 10.9 -11.39 11.4 -11.89 11.9 -12.39 12.4 & Up <br /> HSM .34 .33 .31 .30 .29 .28 <br />PTHP COP 2.6 - 2.69 2.7 - 2.89 2.9 - 3.09 3.10 - 3.29 3.30 - 3.49 3.50 - 3,69 3.70 - 3.89 3.90-4.19 <br /> HSM .38 .37 .34 .32 .30 .29 .27 .26 <br />Electric Strip 1.0 <br />Gas & Other Fuels 1.0 (See Table 9J for Credit Multiplier) <br />1991 Minimums: Central Units-Air Source 6.4 HSPF, Water Source 3.4 COP, Ground Water Source 3.2 COP, PTHP 2.6 COP. <br />1992 Minimums: Central Units-Air Source 6.8 HSPF, Water Source 3.8 COP, Ground Water Source 3.4 COP, PTHP 2.7 COP. <br />HSPF means Heatinq Seasonal Performance Factor. COP means Coefficient of Performance. <br /> <br />9J HEATING CREDIT MULTIPLIERS IHCM) <br /> SYSTEM TYPE HEATING CREDIT MULTIPLIERS <br /> Attic Radiant Barrier HCM .98 <br /> Multizone HCM 90 <br /> Natural Gas AFUE .68 - 72 73. .77 78 -82 83 - .87 88. .92 .93 - UP <br /> HeM .54 .51 .47 .44 .42 .40 <br /> Other Fuels HCM 61 .60 .56 .52 .49 .47 <br /> Where more than one credit is claimed, multiply HCM's together. Enter product on page 4. AFUE means Annual Fuel Utilization Efficiency. <br /> <br />9K COOLING SYSTEM MULTIPLIERS ICSMI <br /> SYSTEM TYPE COOLING SYSTEM MULTIPLIERS <br /> RATING 7.5 - 80 - 85 - 8.9 - 9.5 - 10.0. 10.5 - 11.0 - 115 - 12.0 - <br />CENTRAL UNITS 79 8.4 88 9.4 99 10.4 10.9 114 11.9 12.4 <br /> (SEER) CSM .45 43 .40 .38 .36 .34 .32 .31 .30 .28 <br />PTAC & ROOM UNITS RATING 125 - 130 - 13.5. 14.0. 14.5. 15.0 - 15.5 - 16.0 - 16.5 - 17.0 - 17.5 <br /> (EER) 129 13.4 139 14.4 14.9 15.4 159 16.4 169 17.4 & Up <br /> CSM .27 26 .25 24 24 .23 22 21 21 20 .19 <br />1991 Minimums: Central Units-Air Cooled 89 SEER. Ground Water Cooled 10.0 EER. 1992 Minimums: Central Units-Air Cooled 10.0 SEER. Ground <br />Water Cooled 11.0 EER. PTAC-see Table 9-11A EER means EnerQV Efficiency Ratio. SEER means Seasonal EnerQV Efficiency Ratio. <br /> <br />SL-- <br /> <br />9L COOLING CREDIT MULTIPLIERS ICCM) <br />SYSTEM TYPE COOLING CREDIT MULTIPLIERS (CCM) <br />Ceiling Fans -- .86 <br />Multizone ~- .90 <br />Cross Ventilation or Whole House Fan (Credit for only one) -- .95 <br />Attic Radiant Barrier .95 <br />Where more than one credit is claimed multiolv CCM's tooether. Enter oroduct on Dace 2. <br /> <br />9M HOT WATER MULTIPLIERS HWM\ <br />SYSTEM TYPE HOT WATER MULTIPLIERS <br />Electric EF .80 -81 I .82 - .83 I 84 - .85 I .86. .87 I .88 - .90 I .91. .93 I .94 -96 I .97 & Up <br />ReSistance HWM 3879 I 3785 I 3695 I 3609 I 3527 I 3411 I 3302 I 3200 <br />Natural Gas EF .43 - .47 .48 . .49 .50 - .51 .52 - 53 .54 -55 .56 -57 .58 -59 60. .61 .62 - .63 .64 - .65 .66 & Up <br />HWM 2664 2386 2291 2203 2121 2045 1975 1909 1847 1790 1735 <br />Other Fuels HWM 1845 2059 2145 2231 2317 2234 2157 2085 2018 1955 1895 <br />Water heaters must comply with minimum efficiences in Table 9-7A of the Florida Energy Code. EF means Energy Factor. <br /> <br />9N HOT WATER CREDIT MULTIPLIERS HWCM) <br /> SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS <br />Solar Water Heater SF .1 I .2 I .3 I .4 I .5 .6 I 7 I .8 I .9 I 10 <br /> HWCM .9 I 8 I 7 I 6 I .5 .4 I .3 I .2 I .1 I .0 <br />Heat Recovery Unit With Air{;onditioner Heat Pump <br />HWCM .62 58 <br />Dedicated Heat Pump EF 2.0 . 2.49 I 2.5 - 2.99 30-3.49 I 3.5 & Up <br />HWCM .44 I .35 29 I .25 <br />A HWM must be used in conjunction with all HWCM. See Table 9M. SF means Solar Fraction. EF means Energy Factor. <br /> <br />9P INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECKLIST lSee Section 903.2(1)) <br />COMPONENTS REQUIREMENTS FOR EACH PRACTICE CHECK <br />PRACTICE #1 COMPLY WITH ALL INFilTRATION PRESCRIPTIVES ON TABLE 9A. <br />PRACTICE #2 COMPLY WITH PRACTICE #1 AND THE FOLLOWING: <br />Exterior Walls and Floors Top plate penetrations sealed. Infiltration barrier installed. Sole platelfloor joint caulked or sealed. <br />Exterior Walls & CeilinQs Penetrations, joints and cracks on interior surface caulked, sealed or gasketed. <br />Ductwork Ductwork in unconditioned space must be sealed. <br />Fireplaces Equipped with outside combustion air, doors, and flue dampers. <br />Exhaust Fans Equipped with dampers Combustion devices see 903.2(1). <br />PRACTICE #3 COMPLY WITH PRACTICES #1 AND #2 AND THE FOLLOWING: <br />Ceilings Infiltration barrier installed. <br />Interior Walls Top plate penetrations sealed or loints & cracks on interior walls caulked, sealed or gasketed. <br />Recessed LiQhts Sealed from conditioned soace & insulated from ventilated attic spaces. <br />Ductwork All ductwork located in conditioned space. <br />Combustion Appliances Be in unconditioned space (except direct vent), draw air from unconditioned space, exhaust <br />by-products to outside. Stoves see 903.2(f). <br /> <br />-6- <br />